When choosing the installation location, take account of the following:
●
The wall thickness of the installation surface must be at least 15 mm, as otherwise the screws will break through on
the other side or damage the surface.
●
Ensure that the cupboard or storage compartment in which the unit is housed is adequately ventilated, to prevent a
build-up of heat. Carpet-covered walls are unsuitable for installation
●
Take care when tightening the screws not to damage any cables or similar behind or in the wall
●
The CAP converter is designed exclusively for installation in dry, interior locations.
●
The cable lengths must be taken into account when choosing the installation location
●
The connecting cables must be provided with strain reliefs
Ventilation
The heat generated within the CAP converter can be
dissipated from all sides of the casing. When selecting
the installation location, make sure that these sides are
not obstructed or covered. If the unit is operated contin-
uously with insufficient ventilation, this can negatively
affect the length of its working life!
Maintain a clearance of at least 20 cm above and below
the unit, 2 cm to either side and 5 cm behind and in
front of it, to allow unobstructed dissipation of the heat
generated.
Minimum
clearance
20 cm
2 cm
5 cm
5 cm
2 cm
Risk of material damage due to insufficient ventilation!
The unit monitors its own temperature in operation. Continuous operation at temperatures higher than
the recommended operating temperature can cause premature failure of the unit as a result of insufficient
ventilation. This does not constitute grounds for a claim under warranty/guarantee!
►
Operate the CAP converter only at the recommended operating temperature.
Connections and fusing of the unit
All the connecting cables are connected at the rear of the CAP converter, see also 5.2.6, p. 27.
On the left-hand side of the CAP converter viewed from the front there is a fuse inserted from the outside. This fuse
must be accessible even after the unit has been installed, so that it can easily be exchanged if required. For more infor-
mation about the type of fuse, see the sticker on the CAP converter and the fuse itself.