12
Fault
Possible cause
Remedy
of whom
The indicator lamp Burner
failure (E) blinks.
The exhaust temperature limiter
has been triggered.
Open the hand-spray gun until the plant has
cooled down. Switch the plant off and then on
on the operating panel to unlock the temper-
ature limiter. If the event recurs, call Custom-
er Service.
Operator
Indicator lamp for protection
against calcification (H)
glows
The softener is over.
Refill the softener.
Operator
Inadequate or no flow of de-
tergent
Dosing valve to position "0".
Adjusting the detergent metering valve.
Operator
Detergent filter blocked or tank is
empty.
Clean and/or refill.
Operator
Detergent suction hoses, deter-
gent metering valve or detergent
solenoid valve are leaky or
blocked.
Check, clean.
Operator
Electronics or solenoid valve is de-
fective.
Replace
Customer Service
Full pressure does not build
up in the appliance
Flushed the nozzle.
Replace the nozzle.
Operator
Detergent tank is empty.
Refill detergent.
Operator
Not enough water
Ensure adequate water supply.
Operator
Sieve at the water inlet is blocked. Check, dismantle sieve and clean it.
Operator
Leaky detergent dosing valve.
Check and seal it.
Operator
Leaky detergent hoses.
Replace
Operator
Swimmer valve is jammed.
Check and ensure that it moves freely.
Operator
Safety valve is leaky.
Check the setting; install new washers, if re-
quired.
Customer Service
Flow valve is leaky or has been set
at a low value.
Check valve parts; replace damaged parts;
clean the dirt.
Customer Service
Solenoid valve for pressure re-
lease is defective.
Replace solenoid valve.
Customer Service
High pressure pump is
knocking; manometer is
swaying wildly
Vibration dampener is defective.
Replace vibration dampener.
Customer Service
Water pump does not suck in ade-
quate air.
Check suction system and remove leaks.
Operator
Device continuously turns on
and off while hand spray gun
is open
Nozzle in spray pipe is blocked.
Check, clean.
Operator
Appliance is decalcified.
See section "Descaling".
Operator
Switching point of the over-current
monitor has got shifted.
Get somebody to reset the over-current mon-
itor.
Customer Service
Sieve blocked in the water short-
age safe guard.
Check, dismantle sieve and clean it.
Operator
Appliance does not switch off
when the hand-spray gun is
closed
The pump has not been fully vent-
ed.
Set the machine switch to "0" and pull the
hand-spray gun until no fluid comes out of the
nozzle. Turn on the appliance again. Repeat
this procedure until the full operating pres-
sure is reached.
Operator
Safety valve or safety valve wash-
er is defective.
Replace the safety valve and/or the washer. Customer Service
33
EN
Summary of Contents for HDS 12/14-4 ST Gas
Page 2: ...2...
Page 10: ...8 Ma blatt 700 510 10 DE...
Page 29: ...8 Specifications sheet 700 510 29 EN...
Page 48: ...8 Feuille de mesure 700 510 48 FR...
Page 69: ...9 Disegno dimensionale 700 510 69 IT...
Page 89: ...9 Maatblad 700 510 89 NL...
Page 109: ...8 Hoja de dimensiones 700 510 109 ES...
Page 128: ...8 Folha de dimens es 700 510 128 PT...
Page 147: ...8 M ltegning 700 510 147 DA...
Page 166: ...8 M leblad 700 510 166 NO...
Page 185: ...8 M ttblad 700 510 185 SV...
Page 204: ...8 Mitat 700 510 204 FI...
Page 217: ...2 K rcher 320 C 217 EL...
Page 218: ...3 1 1 2 3 4 5 6 7 8 9 10 11 12 2 A B C D E F G H I 6 5 7 8 3 4 9 11 10 1 12 2 218 EL...
Page 219: ...4 IEC 60364 1 30 cm K rcher 0 219 EL...
Page 222: ...7 30 0 Cekon 222 EL...
Page 224: ...9 700 510 224 EL...
Page 225: ...10 Cekon 40 6 288 016 200 3 3 MPa 0 7 1 MPa 1000 1 l 6 288 016 5 225 EL...
Page 227: ...12 Cekon F3 2 1 WS F1 227 EL...
Page 228: ...13 0 0 228 EL...
Page 235: ...20 235 EL...
Page 236: ...21 236 EL...
Page 244: ...8 l sayfas 700 510 244 TR...
Page 257: ...2 K rcher 320 C 257 RU...
Page 258: ...3 1 1 2 3 4 5 6 7 I 8 II 9 10 11 12 2 A B C I D II E F G H I 6 5 7 8 3 4 9 11 10 1 12 2 258 RU...
Page 259: ...4 IEC 60364 1 30 Karcher 0 259 RU...
Page 262: ...7 Cekon 262 RU...
Page 264: ...9 700 510 264 RU...
Page 265: ...10 Cekon 40 6 288 016 200 3 3 0 7 1 1000 1 6 288 016 5 265 RU...
Page 267: ...12 Cekon F F3 T2 HD ND 1 G WS F1 B I 267 RU...
Page 268: ...13 H 0 0 268 RU...
Page 272: ...17 2 8 8 7 6 5 4 3 2 1 S2 min max 272 RU...
Page 275: ...20 275 RU...
Page 276: ...21 276 RU...
Page 284: ...8 M ret lap 700 510 284 HU...
Page 303: ...8 P ehled rozm r 700 510 303 CS...
Page 322: ...8 Merski list 700 510 322 SL...
Page 341: ...8 Arkusz z wymiarami 700 510 341 PL...
Page 360: ...8 Rozmerov n rtok 700 510 360 SK...
Page 379: ...8 M duleht 700 510 379 ET...
Page 398: ...8 Izm ru tabula 700 510 398 LV...
Page 417: ...8 Matmen lentel 700 510 417 LT...
Page 430: ...2 K rcher 320 C 430 UK...
Page 431: ...3 1 1 2 3 4 5 6 7 I 8 9 10 11 12 2 A B C I D E F G H I 6 5 7 8 3 4 9 11 10 1 12 2 431 UK...
Page 432: ...4 IEC 60364 1 30 K rcher 0 432 UK...
Page 435: ...7 30 0 Cekon 435 UK...
Page 437: ...9 700 510 437 UK...
Page 438: ...10 Cekon 40 6 288 016 200 3 3 0 7 1 1000 1 6 288 016 5 438 UK...
Page 440: ...12 Cekon F F3 T2 HD ND 1 G WS F1 B 440 UK...
Page 441: ...13 H 0 0 441 UK...
Page 448: ...20 448 UK...
Page 449: ...21 449 UK...
Page 450: ...http www kaercher com dealersearch...