11
Danger
Risk of injury! The main switch of the vacuum cleaner is to be
switched off or the Cekon plug must be unplugged while carrying
out any repairs or maintenance jobs.
*
Note
Switch the plant off and then on to undo the burner failure.
**
Troubleshooting
Fault
Possible cause
Remedy
of whom
Machine is not running; indi-
cator lamp for operations
stand-by (F) is not glowing
There is no voltage in the machine. Check electrical mains.
Electrician
Safety time switch is on.
Switch off the appliance switch briefly and
switch it on again.
Operator
Fuse in the control circuit (F3) has
burnt off. Fuse is located in the
control transformer (T2).
Install a new fuse; if it burns out again, then
remove the cause for the over-loading.
Customer Service
Pressure switch HP (High pres-
sure) or LP (Low pressure) is de-
fective.
Check pressure switch.
Customer Service
Timer module (A1) defective.
Check connections, replace if required.
Customer Service
+ Indicator lamp for engine
over-heating (G) is glowing
Thermal sensor (WS) in the engine
or the over-current protection
switch (F1) has got activated.
Rectify cause for over-loading.
Customer Service
The water shortage safeguard in
the swimmer tank has got activat-
ed.
Remove the water shortage.
Operator
Burner does not ignite or the
flame glows off during opera-
tion
Thermostat (B) has been set at a
very low temperature.
Set the thermostat to a higher level.
Operator
Machine switch is not positioned to
burner
Switch on the burner.
Operator
The water shortage safeguard in
the safety block has got switched
off.
Ensure adequate water supply. Check ma-
chine for leaks.
Operator
The indicator lamp Burner
failure (E) glows*
Fuel tank empty.
Refill fuel.
Operator
Fuel filter choked.
Clean fuel filter - to do that remove the fuel fil-
ter by turning, clean it and again turn it in.
Operator
Photo-cell flame monitoring device
has been set wrongly or is defec-
tive.
Check the correct positioning of the photo-
cell. **
Operator
No ignition spark exists (can be de-
tected through the sight glass in
the burner lid).
Check electrodes distance between ignition
transformer and ignition cable. Rectify the
distance or replace defective parts. Clean it,
if necessary.
Customer Service
Ignition motor is locked.
Removing the blockage. Remove the stop-
per (I) on the operating plan and unlock the
over-current protection switch. Insert back
the stopper.
Customer Service
Failure of hte fuel pump or the fuel
solenoid valve.
Check parts and replace defective parts.
Operator
32
EN
Summary of Contents for HDS 12/14-4 ST Gas
Page 2: ...2...
Page 10: ...8 Ma blatt 700 510 10 DE...
Page 29: ...8 Specifications sheet 700 510 29 EN...
Page 48: ...8 Feuille de mesure 700 510 48 FR...
Page 69: ...9 Disegno dimensionale 700 510 69 IT...
Page 89: ...9 Maatblad 700 510 89 NL...
Page 109: ...8 Hoja de dimensiones 700 510 109 ES...
Page 128: ...8 Folha de dimens es 700 510 128 PT...
Page 147: ...8 M ltegning 700 510 147 DA...
Page 166: ...8 M leblad 700 510 166 NO...
Page 185: ...8 M ttblad 700 510 185 SV...
Page 204: ...8 Mitat 700 510 204 FI...
Page 217: ...2 K rcher 320 C 217 EL...
Page 218: ...3 1 1 2 3 4 5 6 7 8 9 10 11 12 2 A B C D E F G H I 6 5 7 8 3 4 9 11 10 1 12 2 218 EL...
Page 219: ...4 IEC 60364 1 30 cm K rcher 0 219 EL...
Page 222: ...7 30 0 Cekon 222 EL...
Page 224: ...9 700 510 224 EL...
Page 225: ...10 Cekon 40 6 288 016 200 3 3 MPa 0 7 1 MPa 1000 1 l 6 288 016 5 225 EL...
Page 227: ...12 Cekon F3 2 1 WS F1 227 EL...
Page 228: ...13 0 0 228 EL...
Page 235: ...20 235 EL...
Page 236: ...21 236 EL...
Page 244: ...8 l sayfas 700 510 244 TR...
Page 257: ...2 K rcher 320 C 257 RU...
Page 258: ...3 1 1 2 3 4 5 6 7 I 8 II 9 10 11 12 2 A B C I D II E F G H I 6 5 7 8 3 4 9 11 10 1 12 2 258 RU...
Page 259: ...4 IEC 60364 1 30 Karcher 0 259 RU...
Page 262: ...7 Cekon 262 RU...
Page 264: ...9 700 510 264 RU...
Page 265: ...10 Cekon 40 6 288 016 200 3 3 0 7 1 1000 1 6 288 016 5 265 RU...
Page 267: ...12 Cekon F F3 T2 HD ND 1 G WS F1 B I 267 RU...
Page 268: ...13 H 0 0 268 RU...
Page 272: ...17 2 8 8 7 6 5 4 3 2 1 S2 min max 272 RU...
Page 275: ...20 275 RU...
Page 276: ...21 276 RU...
Page 284: ...8 M ret lap 700 510 284 HU...
Page 303: ...8 P ehled rozm r 700 510 303 CS...
Page 322: ...8 Merski list 700 510 322 SL...
Page 341: ...8 Arkusz z wymiarami 700 510 341 PL...
Page 360: ...8 Rozmerov n rtok 700 510 360 SK...
Page 379: ...8 M duleht 700 510 379 ET...
Page 398: ...8 Izm ru tabula 700 510 398 LV...
Page 417: ...8 Matmen lentel 700 510 417 LT...
Page 430: ...2 K rcher 320 C 430 UK...
Page 431: ...3 1 1 2 3 4 5 6 7 I 8 9 10 11 12 2 A B C I D E F G H I 6 5 7 8 3 4 9 11 10 1 12 2 431 UK...
Page 432: ...4 IEC 60364 1 30 K rcher 0 432 UK...
Page 435: ...7 30 0 Cekon 435 UK...
Page 437: ...9 700 510 437 UK...
Page 438: ...10 Cekon 40 6 288 016 200 3 3 0 7 1 1000 1 6 288 016 5 438 UK...
Page 440: ...12 Cekon F F3 T2 HD ND 1 G WS F1 B 440 UK...
Page 441: ...13 H 0 0 441 UK...
Page 448: ...20 448 UK...
Page 449: ...21 449 UK...
Page 450: ...http www kaercher com dealersearch...