36
37
EN
Juice Dispenser FSD4000
© K. & M. Holland GmbH
© K. & M. Holland GmbH
Juice Dispenser FSD4000
EN
Subject to technical change without prior notice! Version 2.0, 11/2017
Subject to technical change without prior notice! Version 2.0, 11/2017
8. Troubleshooting
Should a malfunction occur, first, verify the information and tips provided in the table below
and ensure that all instructions have been followed. It is quite possible that the cause is very
minor.
CAUTION
Ensure to disconnect the power and safeguard the equipment from accidental re-
start when working on the juiced dispenser.
WARNING
Referred to the information about “Troubleshooting” listed in the table above. If
necessary, contact a technician.
8.1 Possible malfunctions
Errors are showed via error codes, flashing buttons and door lighting.
Error
Code
Cause
Effect
Sensor error cooling block
E 01
Cable break or short circuit
Standby, cooling system OFF
Sensor error condenser
E 02
Cable break or short circuit
Standby, cooling system OFF
Sensor error bag room
E 03
Cable break or short circuit
Standby, fan function 50%
Cooling block min. alarm,
cooling machine is OFF
E 11
Relay for cooling system
does not switch off
Standby, buttons and door illu-
mination flashing => switch off
the dispenser by pressing the
main switch at the backside
Cooling block min. alarm,
cooling machine is ON
E 12
Relay for cooling system
does not switch on
Standby, error can be canceled
Condenser < Min. Alarm
Temperature
E 21
Relay for cooling system
does not switch off or ambi
-
ent temperature too low
Normal operation, error can be
canceled, but after 30 minutes
the errow will be showed again.
When the error is fixed, the
alarm deletes itself
Condenser > Max. Alarm
E 23
Relay for condenser fan
does not switch on, fan de-
fective, filter dirty
Standby, error can be canceled
Condenser > switch-off
temperature
E 24
Relay for condenser fan
does not switch on, fan de-
fective, filter dirty
Standby, Kältemaschine AUS
Fehler wird netzausfallsicher ge
-
speichert