26
27
EN
Juice Dispenser FSD4000
© K. & M. Holland GmbH
© K. & M. Holland GmbH
Juice Dispenser FSD4000
EN
Subject to technical change without prior notice! Version 2.0, 11/2017
Subject to technical change without prior notice! Version 2.0, 11/2017
7.6 Parameters
In order to achieve a good adaptability of the control software to the different machine versi
-
ons, without having to create their own software variants, the control software has a few para-
meters.
Parameter
Unit
Min
Max
Default
Basic setting
Number of juice lines
2
4
2-4 (depend. o. t. model)
Number of water lines
0
1
1
Position water line (from left)
2
2
2
Button lighting
[No]
[Yes]
[Yes]
Light cup region
[No]
[Yes]
[Yes]
Bag empty
[No]
[Yes]
[Yes]
Tap at same time
1
4
2-4 (depend. o. t. model)
Outlet 1 active
[No]
[Yes]
[Yes]
Outlet 2 active
[No]
[Yes]
[Yes]
Outlet 3 active
[No]
[Yes]
[Yes]
Outlet 4 active
[No]
[Yes]
[Yes]
Outlet 5 active
[No]
[Yes]
[Yes]
Sensor Offsets
Cooling block Sensor
K
-10
10
0
Condenser Sensor
K
-10
10
0
Bag room Sensor
K
-10
10
0
Temperature setpoints
Cooling block set temperature
°C
1
10
2
Cooling block hysteresis
K
1
5
2
Cooling block min. alarm
°C
-2
5
0
Cooling block max. alarm
°C
5
20
14
Condenser min. alarm
°C
0
20
14
Condenser min.
°C
20
40
30
Condenser max.
°C
40
55
45
Condenser max. alarm
°C
55
70
65
Condensor switch off temperature
°C
70
80
70
Bag room
°C
7
20
12
Bag room min. alarm
°C
0
20
5
Bag room max. alarm
°C
10
30
25
Drink temperature display
°C
2
10
7