Automatic Gas Console Advanced Functions
Spirit200a User’s Manual Rev J
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
5-6
Saving a User Created Cutting or Marking Condition
If one of the default cutting or marking parameters must be altered to
achieve the desired quality, the new condition can be saved for later use.
To save a user created cutting or marking condition, use the arrow keys to
scroll off all selections on the status screen. When none of the
parameters are highlighted the “Press F3 to Save Settings” message will
be displayed as shown. Pressing F3 will cause the save confirmation
window to pop up. When this occurs, press ENT to save the condition or
press CLR to cancel the procedure. Pressing ENT will save the settings
for the particular material being cut and a User icon will appear in the
upper right hand corner of the screen. The User icon indicates that the
parameters for the particular material being cut are not factory defaults but
are user created. The factory default condition can be restored as
described later in this section.
Gas Purge
The gas lines can be purged at any time by pressing the Menu key then
the Gas Purge key. The gas pressures are also readjusted at this time.