Installation
Spirit200a User’s Manual Rev J
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
3-12
Postflow Gas Hose
1. Connect one end of the postflow hose to the postflow outlet on the rear
of the AGC. Note that the postflow hose fittings have left hand
threads.
2. Connect the other end of the postflow hose to the postflow inlet on the
5-gang torch valve assembly.
Plasma Gas Hose
1. Connect on end of the plasma hose to the plasma outlet on the rear of
the AGC.
2. Connect the other end of the plasma hose to the plasma inlet on the 2-
gang torch valve assembly.
Shield Gas Hose
1. Connect one end of the shield hose to the shield outlet on the rear of
the AGC.
2. Connect the other end of the shield hose to the shield inlet on the 5-
gang torch valve assembly.
Preflow Gas Hose
1. Connect one end of the preflow hose to the preflow outlet on the rear
of the AGC. Note that the preflow hose fittings have left hand threads.
2. Connect the other end of the preflow hose to the preflow inlet on the 5-
gang torch valve assembly.
5-Gang Manifold Control Cable
1. Connect the 5-gang manifold control cable plug marked P15 to the 5-
gang manifold as shown.
2. Connect the 5-gang manifold control cable plug labeled P12 to the
connector labeled P12 on the rear of the power supply.
2-Gang Manifold Control Cable
1. Connect the 2-gang manifold control cable plug marked P18 to the 2-
gang manifold as shown.
2. Connect the 2-gang manifold control cable plug labeled P13 to the
connector labeled P13 on the rear of the power supply.
21
18
19
20
23
22