Automatic Gas Console Advanced Functions
Spirit200a User’s Manual Rev J
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
5-4
Altering Gas Pressures
Normally, the preflow gas and plasma gas pressures should not be
changed. The shield gas can be adjusted in small increments to fine-tune
a cut. To alter the gas pressures, use the arrow keys to scroll to the
appropriate pressure setting. The pressure setting should be highlighted
as shown and the editing cursor should be blinking. Use the numerical
keypad to enter the desired operating pressure. Use the CLR key to
backspace if an error is made. Press ENT when the correct value has
been entered. Note that all of the gases have minimum and maximum
limits and cannot be programmed beyond these limits.