Operation
Spirit200a User’s Manual Rev J
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
4-3
Automatic Gas Console Keypad
All cutting information is entered on the keypad of the automatic gas
console as shown below. This section provides a description of each key
and its function.
Menu Key
The Menu key is used to select the bottom portion of a split-level key.
When the Menu key is pressed, a menu icon will appear in the upper right
hand corner of the screen. Pressing the Menu key again will clear the
icon and return to the previous mode. Pressing a split-level key while the
menu icon is visible will enter the specified mode. The following is a list
and description of menu key functions:
Menu + Material
:
Enters the material editing mode
Menu + Current
:
Enters the current editing mode
Menu + Voltage
:
Displays the voltage screen
Menu + Preflow Gas
: Enters the preflow gas editing mode
Menu + Plasma Gas
: Enters the plasma gas editing mode
Menu + Shield Gas
: Enters the shield gas editing mode
Menu + Pierce Delay
: Enters the pierce time editing mode
Menu + Maint
:
Enters the maintenance mode
Menu + Gas Purge
: Purges the cutting gases
Menu + Status
:
Displays the main status screen