Serial Communication
Spirit200a User’s Manual Rev J
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
6-4
RS-422 Serial Commands
Note: In the following commands, “nn” represents the net node of the power
supply that is to receive the command. To send a global command to all power
supplies in a network configuration, “nn” should be set to C8 hex (200 decimal).
The “-- --” in the hex string is the MSB followed by the LSB of a type int. The
integer is the value found in the additional information column.
Command
# Hex String
Additional Information
Set Material Type
1 AA nn FA 01 00 -- 0D
00 = Mild Steel – Hot Rolled
01 = Stainless Steel
02 = Aluminum
03 = Other
04 = Mild Steel – Cold Rolled
Set Thickness
2 AA nn FA 02 -- -- 0D
Thickness in mils (inches x 1000)
Valid Range: 0 to 2000
Set Operating
Current
3 AA nn FA 03 00 -- 0D
01 = 30A
02 = 50A
03 = 70A
04 = 100A
05 = 150A
06 = 200A
0A = 260A
0B = 275A
0C = 400A
Set Cutting Pierce
Time
4 AA nn FA 04 -- -- 0D
Cutting pierce time in ms
Valid Range: 0 to 9999
Set Preflow
Pressure
6 AA nn FA 06 -- -- 0D
Preflow psi x 10
Valid Range: 0 to 1200
Set Plasma Gas
Type
7 AA nn FA 07 00 -- 0D
00 = Oxygen
02 = Air
04 = H17
Set Plasma
Pressure
8 AA nn FA 08 -- -- 0D
Plasma psi x 10
Valid Range: 0 to 1200
Set Shield Gas Type 9 AA nn FA 09 00 -- 0D
00 = Oxygen
01 = Nitrogen
02 = Air
Set Shield Pressure 10 AA nn FA 0A -- -- 0D
Shield psi x 10
Valid Range: 0 to 1200
Cutting Travel
Speed
15 AA nn FA 0F -- -- 0D
If requested in command #30, the AGC
will transmit the cutting travel speed in
inches per minute. Range: 0 to 999