Automatic Gas Console Advanced Functions
Spirit200a User’s Manual Rev J
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
5-20
Setting an Arc Off Delay
In some instances, such as when cutting thicker stainless steel materials,
it may be desirable to delay the extinction of the cutting arc after a stop
signal is received. To program an arc off delay, scroll down to the Set Arc
Off Delay selection on the Maintenance Screen and press enter. The Set
Arc Off Delay screen will be displayed as shown. Use the keypad to enter
the desired delay time in milliseconds. The delay can be set from 0 to
2000 mS.