Section 5 Automatic Gas Console
Advanced Functions
This section describes how to operate the Spirit system when non-
standard cutting or marking conditions are desired. Instructions are also
given on how to access the various maintenance modes of the system.
Altering the Current Set Point
To alter the current set point from the default setting, use the arrow keys
to scroll to Current Set Point, or press the Menu key then the Current key.
The current setting should be highlighted as shown and the set point
should be blinking. Press F3 to scroll through the available current
choices. The current can only be set to values of 30, 50, 70, 100, 150, or
200 amps when cutting. When marking, the current cannot be changed.
Once the desired value is blinking, press ENT.