Automatic Gas Console Specifications
Stock Number ................................................... 282002
Height ................................................................ 9 in (229 mm)
Width ................................................................. 25 in (635 mm)
Depth ................................................................ 23.8 in (605 mm)
Weight ............................................................... 110 lb (50 kg)
Gas Supply Requirements
Plasma gas types:
Mild Steel ............................................... Oxygen or Air
Stainless Steel ....................................... Air or H17
Aluminum ............................................... Air
Shield gas types:
Mild Steel ............................................... Oxygen or Air
Stainless Steel ....................................... Air or Nitrogen
Aluminum ............................................... Air or Nitrogen
Preflow gas type .......................................... Oxygen and Nitrogen
Marking gas type .......................................... Nitrogen
Plasma gas flow rate (maximum):
Oxygen or Air ......................................... 67 scfh (1897 liters/hour)
H17 ......................................................... 75 scfh (2124 liters/hour)
Shield gas flow rate (maximum):
Oxygen ................................................... 19 scfh (538 liters/hour)
Air or Nitrogen ........................................ 225 scfh (6371 liters/hour)
Preflow gas flow rate (maximum) ................. 60 scfh (1699 liters/hour)
Marking gas flow rate (maximum) ................ 77 scfh (2180 liters/hour)
Rated Inlet gas pressures ....................................... 120 psi (8.3 bar)
Maximum Inlet gas pressure………………………….145 psi (10.0 bar)
Oxygen and nitrogen should be supplied with a purity of at least 99.5%.
H17 should be supplied with a purity of at least 99.995%.
A potential fire
hazard exists when cutting with oxygen. KALIBURN recommends
that an exhaust ventilation system be used when cutting with
oxygen. Flashback arrestors must be supplied (unless they are not
available for the chosen gases and pressures) to prevent a possible
fire from propagating back to the gas supplies.
Ensure that oxygen
lines remain free from contaminants such as oil and grease. The mixture
of such contaminants with oxygen presents an additional fire hazard.
Compressed air must be clean, dry, and oil-free and may be supplied from
compressed cylinders or from an air compressor. Be aware that shop air
systems are prone to oil and moisture contamination. If shop air is used, it
must be cleaned to ISO 8573.1: Class 1.4.1. Specify dry air when using
compressed cylinders. Breathing quality air contains moisture and must
not be used. 3/8” (inside diameter) hoses are required for all inlet gas
connections. Mating connectors are supplied with the unit.
Quick-connect fittings must not be used.