4) For Pumpc and DHW pipe pump:
KM3
Power supply
7 5 3 1 A1
A2
2
4
6
8
KM7
Power supply
7 5 3 1 A1
A2
2
4
6
8
�
�
����
CN11
25 26
1
2 3 4 5
6 7 8 9 10
CN7
CN30
27 28
29 30 31 32
9
21
�
�
����
CN11
25 26
1
2 3 4 5
6 7 8 9 10
CN7
CN30
27 28
29 30 31 32
12
24
Pumpc(zone2 pump)
P-d
DHW pipe pump
a) Procedure
Connect the cable to the appropriate
terminals as shown in the picture.
Fix the cable reliably.
CN5
Control port signal type
Voltage
Maximum running current(A)
Wiring size(mm
2
)
Type 2
220-240VAC
0.2
0.75
Voltage
Maximum running current(A)
Wiring size(mm
2
)
220-240VAC
0.2
0.75
Room thermostat type 1(High voltage): "POWER IN" provide the working
voltage to the RT, doesn’t provide the voltage to the RT connector directly. Port
"15 L1" provide the 220V voltage to the RT connector. Port "15 L1" connect
from the unit main power supply port L of 1- phase power supply.
Room thermostat type 2(Low voltage) : "POWER IN" provide the working
voltage to the RT.
5) For room thermostat:
Method B
RT1
C
POWER
IN
H
Method A
RT1
POWER
IN
Room thermostat type 1 (High voltage):
Method C
RT1
POWER IN
RT2
POWER IN
3
15
4
�
�
����
CN11
25 26
1
2 3 4 5
6 7 8 9 10
CN7
CN30
27 28
29 30 31 32
15
3 4
�
�
����
CN11
25 26
1
2 3 4 5
6 7 8 9 10
CN7
CN30
27 28
29 30 31 32
15
3
�
�
����
CN11
25 26
1
2 3 4 5
6 7 8 9 10
CN7
CN30
27 28
29 30 31 32
15
3 4
L1
L1
H
C
H
L1
There are two optional connect method depend on
the room thermostat type.
NOTE
There are three methods for connecting the thermostat cable (as described in the
picture above) and it depends on the application.
Method A
RT can control heating and cooling individually, like the controller for 4-pipe FCU. When
the hydraulic module is connected with the external temperature controller, user
interface FOR SERVICEMAN set ROOM THERMOSTAT to MODE SET
:
A.1 When unit detect voltage is 230VAC between C and L1 ,the unit operates in the
cooling mode.
A.2 When unit detect voltage is 230VAC between H and L1, the unit operates in the
heating mode.
A.3 When unit detect voltage is 0VAC for both side(C-L1, H-L1) the unit stop working
for space heating or cooling.
A.4 When unit detect voltage is 230VAC for both side(C-L1, H-L1) the unit working in
cooling mode.
Method B
RT provide the switch signal to unit. User interface FOR SERVICEMAN set ROOM
THERMOSTAT to ONE ZONE
:
B.1 When unit detect voltage is 230VAC between H and L1, unit turns on.
B.2 When unit detect voltage is 0VAC between H and L1, unit turns off.
zone1
zone2
(
Mode set control
)
(
One zone control
)
(
Mode set control
)
(
One zone control
)
(
Double zone control
)
KM2
Power supply
7 5 3 1 A1
A2
2
4
6
8
�
����
CN11
25 26
1 2 3 4 5
6 7 8 9 10
CN7
CN30
27 28
29 30 31 32
�
10
22
a) Procedure
Connect the cable to the appropriate terminals as
shown in the picture.
Fix the cable with cable ties to the cable tie mountings
to ensure stress relief.
Control port signal type
Voltage
Maximum running current(A)
Wiring size(mm
2
)
0.2
0.75
Type 2
220-240VAC
For outside circulation pump P_o:
136
Summary of Contents for KHC-06RY1
Page 1: ...INSTRUKCJA INSTALACYJNA INSTALATIONMANUAL POMPA CIEP A MONO MONO TYPE HEAT PUMP PL EN...
Page 2: ......
Page 87: ...87...
Page 88: ......
Page 110: ...Tank booster heater n d e d n d Automatic air purge valve r d r manometer d r 110...
Page 161: ...9 5 10 4 161...
Page 171: ...20 21 Automatic air purge valve Pressure relief valve 171...
Page 174: ...NOTE 174...
Page 175: ...NOTE 175...
Page 176: ...kaisai com...