Go to MENU> FOR SERVICEMAN> 8.HOLIDAY AWAY
SETTING. Press OK. The following page will be
displayed:
The HOLIDAY AWAY SETTING is used to set the outlet
water temperature to prevent freezing when away for
holiday.
10.5.8 HOLIDAY AWAY SETTING
Press ▼ ▲ to scroll and set the phone number. The
maximum length of the phone number is 13 digits, if the
length of phone number is short than 12, please input ■,
as shown below:
Go to MENU> FOR SERVICEMAN>SERVICE CALL.
Press OK. The following page will be displayed:
The installers can set the phone number of the local
dealer in SERVICE CALL SETTING. If the unit doesn’t
work properly, call this number for help.
10.5.9 SERVICE CALL SETTING
ADJUST
OK
CONFIRM
20°C
20°C
8 HOLIDAY AWAY SETTING
8.1 T1S_H.A._H
8.2 T5S_H.A._DHW
ADJUST
9 SERVICE CALL SETTING
PHONE NO. ******************
MOBILE NO. ******************
About ROOM THERMOSTAT
The ROOM THERMOSTAT is used to set whether the
room thermostat is available.
How to set the ROOM THERMOSTAT
Go to MENU> FOR SERVICEMAN> 6.ROOM
THERMOSTAT. Press OK. The following page will be
displayed:
10.5.6 ROOM THERMOSTAT
NON
6 ROOM THERMOSTAT
6.1 ROOM THERMOSTAT
ADJUST
If you set DOUBLE ZONE and ROOM TEMP. to YES,
meanwhile set WATER FLOW TEMP. to YES or NON,the
following page will be displayed.
Homepage (zone 1)
2
Addition page (zone 2)
(Double zone is effective)
◄
◄
In this case, the setting valve of zone 1 is T1S,the setting
valve of zone 2 is T1S2 (The corresponding TIS2 is
calculated according to the climate related curves.)
In this case, the setting valve of zone 1 is T1S,the setting
valve of zone 2 is T1S2.
Go to MENU> FOR SERVICEMAN> 7.OTHER HEATING
SOURCE, Press OK. The following page will be dispayed:
The OTHER HEATING SOURCE is used to set the
parameters of the backup heater, additional heating
sources and solar energy kit.
10.5.7 Other HEATING SOURCE
ROOM THERMOSTAT = NON, no room
thermostat.
ROOM THERMOSTAT = MODE SET, the wiring
of room thermostat should follow method A.
ROOM THERMOSTAT=ONE ZONE, the wiring of
room thermostat should follow method B.
ROOM THERMOSTAT=DOUBLE ZONE, the
wiring of room thermostat should follow method C
(refer to 9.7.6 "Connection for other
components/For room thermostat")
NOTE
30MIN
-5°C
5°C
30MIN
5°C
7 OTHER HEATING SOURCE
7.1 dT1_IBH_ON
7.2 t_IBH_DELAY
7.3 T4_IBH_ON
7.4 dT1_AHS_ON
7.5 t_AHS_DELAY
ADJUST
1/2
-5
°C
7 OTHER HEATING SOURCE
7.6 T4_AHS_ON
7.7 IBH LOCATE PIPE LOOP
7.8 P_IBH1
7.9 P_IBH2
7.10 P_TBH
ADJUST
2/2
0.0kW
0.0kW
2.0kW
The number displayed on the user interface is the phone
number of your local dealer.
The RESTORE FACTORY SETTING is used to restore
all the parameters set in the user interface to the factory
setting.
10.5.10 RESTORE FACTORY SETTINGS
TEST RUN is used to check correct operation of the
valves, air purge, circulation pump operation, cooling,
heating and domestic water heating.
10.5.11 TEST RUN
Go to MENU> FOR SERVICEMAN> 10.RESTORE
FACTORY SETTINGS. Press OK. The following page will
be displayed:
Press
▼
▲
to scroll the cursor to YES and press OK. The
following page will be displayed:
After a few seconds, all the parameters set in the user
interface will be restored to factory settings.
Go to MENU> FOR SERVICEMAN> 11.TEST RUN.
Press OK. The following page will be displayed:
If YES is selected, the following pages will be displayed:
10 RESTORE FACTORY SETTINGS
All the settings will come back to
factory default.
Do you want to restore factory
settings?
OK
CONFIRM
NO
YES
11 TEST RUN
Active the settings and
active the “TEST RUN”?
OK
CONFIRM
NO
YES
Please wait…
5%
10 RESTORE FACTORY SETTINGS
If POINT CHECK is selected, the following pages will be
displayed:
Press ▼ ▲ to scroll to the components you want to check
and press ON/OFF. For example, when 3-way valve is
selected and ON/OFF is pressed, if the 3-way valve is
open/close, then the operation of 3-way valve is normal,
and so are other components.
11 TEST RUN
Test run is on.
Air purge is on.
OK
CONFIRM
11 TEST RUN
OFF
OFF
OFF
OFF
OFF
ON/OFF
ON/OFF
3-WAY VALVE 1
3-WAY VALVE 2
PUMP I
PUMP O
PUMP C
ADJUST
OK
CONFIRM
9 SERVICE CALL
PHONE NO. ***************
MOBILE NO. ******************
1/2
11 TEST RUN
OFF
OFF
OFF
OFF
OFF
ON/OFF
ON/OFF
PUMPSOLAR
PUMPDHW
INNER BACKUP HEATER
TANK HEATER
3-WAY VALVE 3
2/2
If you select AIR PURGE and OK is pressed, the following
page will be displayed :
Before the point check, make sure the tank and
the water system is filled with water, and air is
expelled, or it may cause the pump or backup
heater burn out.
CAUTION
OK
ENTER
11 TEST RUN
11.1 POINT CHECK
11.2 AIR PURGE
11.3 CIRCULATED PUMP RUNNING
11.4 COOL MODE RUNNING
11.5 HEAT MODE RUNNING
OK
ENTER
11 TEST RUN
11.6 DHW MODE RUNNING
147
Summary of Contents for KHC-06RY1
Page 1: ...INSTRUKCJA INSTALACYJNA INSTALATIONMANUAL POMPA CIEP A MONO MONO TYPE HEAT PUMP PL EN...
Page 2: ......
Page 87: ...87...
Page 88: ......
Page 110: ...Tank booster heater n d e d n d Automatic air purge valve r d r manometer d r 110...
Page 161: ...9 5 10 4 161...
Page 171: ...20 21 Automatic air purge valve Pressure relief valve 171...
Page 174: ...NOTE 174...
Page 175: ...NOTE 175...
Page 176: ...kaisai com...