When the cursor is on OPERATE PREHEATING FOR
FLOOR, Use
▼
▲
to scroll to YES and press OK. The
following page will be displayed:
Press ▼ ▲ to scroll and press OK to enter.
During first operation of the unit, air may remain in the
water system which can cause malfunctions during
operation. It is necessary to run the air purge function to
release the air (make sure the air purge valve is open).
Go to MENU> FOR SERVICEMAN> 12.SPECIAL
FUNCTION.
Before floor heating, if a large amount of water remains on
the floor, the floor may be warped or even rupture during
floor heating operation, in order to protect the floor, floor
drying is necessary, during which the temperature of the
floor should be increased gradually.
OK
ENTER
12 SPECIAL FUNCTION
12.1 PREHEATING FOR FLOOR
12.2 FLOOR DRYING UP
If PREHEATING FOR FLOOR is selected, after press OK,
the following page will be displayed:
12.1 PREHEATING FOR FLOOR
30
°C
72 HOURS
ADJUST
T1S
t_fristFH
ENTER
EXIT
Use
▼
▲
to scroll the cursor to YES and press OK, the
preheating for floor will turn off.
The operation of the unit during preheating for floor
described in the picture below:
During preheating for floor, all the buttons except OK are
invalid. If you want to turn off the preheating for floor,
please press OK.
The following page will be displayed:
12.1 PREHEATING FOR FLOOR
Preheat for floor is
running for 25 minutes.
Water flow temperature is 20°C.
OK
CONFIRM
12.2 FLOOR DRYING UP
8
days
5 days
5 days
45°C
15:00
ADJUST
WARM UP TIME(t_DRYUP)
KEEP TIME(t_HIGHPEAK)
TEMP. DOWN TIME(t_DRYDOWN)
PEAK TEMP.(T_DRYPEAK)
START TIME
12.1 PREHEATING FOR FLOOR
Do you want to turn off the preheating
for floor function?
OK
CONFIRM
NO
YES
12.2 FLOOR DRYING UP
01
-01-2019
ADJUST
START DATE
ENTER
EXIT
12 SPECIAL FUNCTION
Active the settings and active the
“SPECIAL FUNCTION”?
OK
CONFIRM
NO
YES
If FLOOR DRYING UP is selected, after press OK , the
following pages will be displayed:
149
Summary of Contents for KHC-06RY1
Page 1: ...INSTRUKCJA INSTALACYJNA INSTALATIONMANUAL POMPA CIEP A MONO MONO TYPE HEAT PUMP PL EN...
Page 2: ......
Page 87: ...87...
Page 88: ......
Page 110: ...Tank booster heater n d e d n d Automatic air purge valve r d r manometer d r 110...
Page 161: ...9 5 10 4 161...
Page 171: ...20 21 Automatic air purge valve Pressure relief valve 171...
Page 174: ...NOTE 174...
Page 175: ...NOTE 175...
Page 176: ...kaisai com...