8.1 Application 1
The application examples given below are for illustration only.
8 TYPICAL APPLICATIONS
3
5
6
7
8
4
4.2
4.1
10
13
18
11.2
11
11.3
11.1
13
17
FHL1
FHL2
FHLn
19
20
Outdoor
Indoor
1
4.3
6.1
9
AHS
13
16
2
Modbus
15
16
14
12
14
6.2
Code
Assembly unit
Code
Assembly unit
1
Main unit
11
Domestic hot water tank (Field supply)
2
11.1
TBH: Domestic hot water tank booster
heater (Field supply)
3
SV1:3-way valve (Field supply)
11.2
Coil 1, heat exchanger for heat pump
11.3
Coil 2, heat exchanger for Solar energy
4.1
Automatic air purge valve
12
Filter (Accessory)
4.2
Drainage valve
13
Check valve (Field supply)
4.3
Tbt1: Balance tank upper temperature
sensor (Optional )
14
Shut-off valve (Field supply)
15
Filling valve (Field supply)
16
Drainage valve (Field supply)
17
Tap water inlet pipe (Field supply))
18
Hot water tap (Field supply)
19
Collector/distributor (Field supply)
20
Bypass valve (Field supply)
FHL
1…n
Floor heating loop (Field supply)
AHS
Auxiliary heat source (Field supply)
User interface
4
Balance or buffer tank (Field supply)
5
P_o: Outside circulation pump (Field supply)
6
P_s: Solar pump (Field supply)
6.1
Tsolar: Solar temperature sensor (Optional)
6.2
Solar panel (Field supply)
7
P_d: DHW pipe pump (Field supply)
8
T5: Domestic water tank temperature
sensor (Accessory)
9
T1:Total water flow temperature sensor
(Optional)
10
Expansion vessel (Field supply)
104
Summary of Contents for KHC-06RY1
Page 1: ...INSTRUKCJA INSTALACYJNA INSTALATIONMANUAL POMPA CIEP A MONO MONO TYPE HEAT PUMP PL EN...
Page 2: ......
Page 87: ...87...
Page 88: ......
Page 110: ...Tank booster heater n d e d n d Automatic air purge valve r d r manometer d r 110...
Page 161: ...9 5 10 4 161...
Page 171: ...20 21 Automatic air purge valve Pressure relief valve 171...
Page 174: ...NOTE 174...
Page 175: ...NOTE 175...
Page 176: ...kaisai com...