PAXOS advance Series
II_PAXOS_V001_20161007_EN
41
Installation Instructions
Installation
4.8.5 Commissioning
Proceed as follows to commission the Paxos advance:
1.
Following completion of the installation work, place the locking system Paxos advance
into operation in accordance with the details in
section 6 “Addressing/functional check of the
and complete the addressing and functional checks.
Following completion of the fault-free addressing and functional checks of the locking
system, proceed with the next step.
2.
Activate the opening codes OCa1 and OCb1 as well as the master code MA1 for door
lock 1, by assigning them individual codes
(see Operating Manual, section 5.2.4.1 “Setting the
Opening Code OCa.., OCb.. and Master Code“)
.
Note: The remote lock function can only be activated if the opening codes OCa1 and OCb1
and the master code MA1 for door lock 1 are activated.
3.
Activate the remote lock function in the menu by selecting Settings>Lock 1
(see Operating
Manual, section 5.4.2.7 “Enabling/disabling the Remote Lock function“)
.
The locking system Paxos advance is now configured to be operated as a blocking element.
Approval to open the door locks or the opening blocks of the door locks is now only granted by
the hazard alert/intrusion detection system.
–
If control input 1 (terminals 1 and 2) is open, the locking system is blocked and the door
locks cannot be opened.
–
If control input 1 (terminals 1 and 2) is closed and the correct impedance (1 Rx) is detected,
the remote lock is deactivated and the door locks can be opened.
The remote lock function is automatically deactivated by deleting master code MA1.
CLAVIS Deutschland GmbH
Grüner Weg 38
34117 Kassel
Telefon: +49 (0)561 988 499-0
E-Mail: [email protected]
Internet: www.tresore.eu
www.tresorschloss.de
Customer Service