36 II_PAXOS_V001_20161007_EN
PAXOS advance Series
Installation
Installation Instructions
4.8.3 Connection work
The following section details the electrical connections between the I/O-Box and hazard alert
or intrusion detection system that must be implemented to operate the locking system Paxos
advance as a blocking element. If required, in- and outputs of the I/O-Box that are not used can
be connected to the hazard alert or intrusion detection system in accordance with the details in
section 5.3 “External connections on the I/O-Box”
.
Note the following:
–
Route all of the connection cables to the I/O-Box through the relevant opening in the
cover “VdS blocking element”.
–
The following connection diagram illustrates the wiring of the hazard alert or intrusion
detection system and the lifting contact of the cover “VdS blocking element” with the
relevant in- and outputs of the I/O-Box in accordance with the factory configuration. For
this purpose, also observe the following information.
A
S3
8
4
AS384 Management-Suite Software
The AS384 Management-Suite Software can be used to reconfigure the functions of the in- and
outputs. If the functionality of the in- and outputs is reconfigured, ensure that the connections
to and from the hazard alert or intrusion detection system and the lifting contact of the cover
“VdS blocking element” are connected to the correct connections of the I/O-Box.
I/O-Box
16
17
GND
IN4
14
15
+
–
12...24 VDC
GND
12 VDC ... 24 VDC
700 ... 200 mA
GND
–
+
NC
6.8 kΩ
6.8 k
Ω
1
2
GND
IN1
1
2
3
4
9
10
Cover “VdS blocking element”
(positioning of the contacts in the assembled state)
Hazard alert/intrusion
detection system
Uninterruptible
power supply
Locking status
Remote locking signal
(positioning of the contacts with remote locking activated)
Connection diagram for operating the locking system
Paxos advance
as a blocking element (
factory
configuration
)
Summary of Contents for PAXOS advance Series