PAXOS advance Series
II_PAXOS_V001_20161007_EN 55
Installation Instructions
Electrical Installation
5.4.2 IP-Box connection data
Terminal
Description
Capacity/Comments
1 (IN1) / 2 (GND) **
Input 1
Standard: Remote lock
12 ... 24 VDC (min. 5 mA)
* Connection without tamper
monitoring circuit (factory
configuration):
INx
GND
ext.
IP-Box
** Connection with tamper
monitoring circuit (factory
configuration):
INx
GND
6.8 kΩ
6.8 k
Ω
ext.
IP-Box
3 (IN2) / 4 (GND) *
Input 2
Standard: Bypass opening delay
5 (IN3) / 6 (GND) *
Input 3
Standard: Time lock interruption
7 (OUT1) / 8 (OUT1)
Output 1
Standard: Lock 1 open
Voltage load at the output:
Max. 24 VAC
Current load at the output:
Max. 0.4 A at 25°C
Max. 0.3 A at 50°C
OUTx
NC
OUTx
ext.
IP-Box
Note: the standard setting (NC:
normally closed) can be changed
via the AS384 Management-Suite
Software, if the standard (see
description in the table) does not
apply.
9 (OUT2) / 10 (OUT2)
Output 2
Standard: All locks and door bolts
open