46 II_PAXOS_V001_20161007_EN
PAXOS advance Series
Installation
Installation Instructions
4.10 Using the IP-Box for the operation as blocking element
The locking system Paxos advance equipped with the optional IP-Box can be used as a blocking
element (according to VdS) to control the locking system and a hazard alert or intrusion detection
system.
The locking system Paxos advance equipped with the optional IP-Box can also be used as a lock
monitoring system or burglar alarm in accordance with VdS.
4.10.1 Required components
The following components are required for operating the locking system Paxos advance
as
a blocking element:
–
A locking system Paxos advance with lock class B (EN1300) / 2 (VdS 2396) or a locking
system Paxos advance with lock class with lock class C (EN1300) / 3 (VdS 2396)
–
Additional locks for locking systems with lock classes B (EN1300) / 2 (VdS 2396) or C (EN
1300) / 3 (VdS 2396)
–
Optional IP-Box
–
External uninterruptible power supply from the hazard alert or intrusion detection system
or an uninterruptible power supply unit
4.10.2 Functional description
When operating the locking system Paxos advance as a blocking element in accordance with
VdS, special in- and outputs of the IP-Box indicate standby activation to the hazard alert/intrusion
detection system or prevent the locking system from being opened when the hazard alert/
intrusion detection system is activated.
Locking process (activation of the hazard alert system)
The locking process starts automatically as soon as the door bolt contacts are closed, or if the
locking mode is set to “Manual lock” as soon as the <ENTER> key or the dial knob on the input
unit is pressed.
As soon as the lock bolt is closed, the “Locking status” signal output of the hazard alert or intrusion
detection system indicates that the locking system is secured. The remote lock contact can be
used to activate the remote lock via the hazard alert or intrusion detection system and arm the
system. The locking system can no longer be opened.
Unlocking process (deactivation of the hazard alert system)
The remote lock must be deactivated via the remote lock contact of the hazard alert or intrusion
detection system so that the locking system can be opened again (disarmed). The lock(s) can be
opened again as soon as the remote lock is deactivated. When the locks and door bolt contacts
are open, the “Locking status” signal output of the hazard alert or intrusion detection system
indicates that the locking system is unlocked.
Summary of Contents for PAXOS advance Series
Page 62: ......