30 II_PAXOS_V001_20161007_EN
PAXOS advance Series
Installation
Installation Instructions
4.5
Mounting the door bolt/door position contacts
Door bolt contacts (mandatory)
The customer must install two electrically separated door bolt contacts into the electronic
high-security locking system Paxos advance that signal to the door locks when the door bolt is
closed. The door bolt contacts must be installed in such a way that they are secured when in the
closed position.
The door bolt contacts must be positioned and set in such a way that the contacts close as soon
as the boltwork reaches a position where the lock bolt can move into the locked position without
any interference.
When in a secured position, the door bolt contacts must not open when manipulated via the boltwork
(activation of the boltwork mechanism, vibrations).
The door bolt contacts must be designed for a switching capacity of 50 mA at 12 VDC.
Door position contacts (optional)
The customer can also install two electrically separated door position contacts that can be
switched in series to the door bolt contacts to signal the position of the container door (open or
closed).
The door position contacts must be positioned and set in such a way that when the door is being
closed, the contacts are activated safely before the door bolt can be inserted into the door frame.
The door position contacts must be designed for a switching capacity of 50 mA at 12 VDC.
The contact circuits of the two redundant door bolt contacts and the two redundant door position
contacts (if provided) must remain electrically separated (galvanically separated). However,
a mechanical coupling, for example by common activation of the switches, is permissible.
Optional
Mandatory
Door position contact A
Door bolt contact A
Door position contact B
Door bolt contact B
First door lock