Addressing/functional check of the system
6
Addressing/functional check of the system
Requirement: The addressing and functional check of the system described below must be
implemented when the container door is open.
Proceed as follows to implement the addressing and functional check of the system:
Insert the batteries/rechargeable battery pack and/or switch on the external power supply
1.
Batteries must be inserted into the battery pack based on the markings – observe the
polarity. The battery pack or dorma+kaba rechargeable battery pack must then be inserted
into the battery compartment (only one position possible).
If your system is connected to a non-fail safe power supply via the I/O- or IP-Box, a battery/
rechargeable battery pack must be inserted in the battery compartment of the input unit
to ensure power is supplied to the system in the event of a power failure. If the locking system
contains more than one input unit, then a battery/rechargeable battery pack is to be inserted
into each input unit. The input unit control automatically detects whether a battery pack is
inserted in the battery compartment and charges it while operating with an external power
source.
If the I/O- or IP-Box is connected to an uninterruptible power supply (UPS), a battery/rechargeable
battery pack does not need to be inserted in the battery compartment of the input unit.
2.
Then insert from below the battery holder (with or without the batteries or rechargeable
battery pack) into the input unit as shown below (the holder must snap into the input unit).
Battery pack
7
PRS
8
TUV
9
WXY
CLR
ENTER
4
GHI
5
JKL
6
MN
1
PRS
2
ABC
0
OQZ
3
DEF
dorma+kaba rechargeable battery pack