Ensure that the rack is stable and secured to the building.
•
Ensure there is enough space to place the uninstalled router in its new location and along the path to
the new location (see
“Clearance Requirements for Airflow and Hardware Maintenance for an MX10016”
•
Review
“General Safety Guidelines and Warnings” on page 273
.
•
Review the chassis lifting guidelines described in
“MX10016 Chassis Lifting Guidelines” on page 279
•
Ensure that the router has been safely powered off (see
“Powering Off an MX10016 Router” on page 238
CAUTION:
When removing more than one router chassis from a rack, remove the routers
in order from top to bottom.
Ensure that you have the following parts and tools available to remove the router:
•
A mechanical lift rated for 500 lbs. (226.8 kg)
•
A Phillips (+) screwdriver, number 2 or number 3, depending on the size of your rack-mounting screws
To removethe router using a mechanical lift (see
):
1. Use the appropriate Phillips (+) screwdriver to remove the 14 mounting screws that attach the chassis
flange to the rack.
2. Move the lift to the rack and position the lift so that its platform is centered about 0.5 in. (1.27 cm)
below the bottom of the router chassis and as close to the chassis as possible.
3. Carefully slide the router from the adjustable base brackets attached to the rack onto the lift.
4. Move the lift away from the rack and lower the lift.
5. Use the lift to transport the router to its new location.
241
Summary of Contents for MX10016
Page 1: ...MX10016 Universal Routing Platform Hardware Guide Published 2019 10 15 ...
Page 19: ......
Page 86: ......
Page 123: ......
Page 153: ......
Page 239: ...Figure 118 Moving the MX10016 Using a Mechanical Lift g100421 242 ...
Page 240: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 245 Alarm Messages 249 ...
Page 241: ......
Page 249: ......
Page 277: ...Restricted Access Warning 281 ...
Page 292: ...Jewelry Removal Warning 296 ...
Page 295: ...Operating Temperature Warning 299 ...
Page 304: ...DC Power Disconnection Warning 308 ...
Page 308: ...DC Power Wiring Sequence Warning 312 ...
Page 311: ...DC Power Wiring Terminations Warning 315 ...
Page 320: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 324 ...