Figure 31: LEDs on a JNP10K-PWR-DC Power Supply in an MX10016
3
—
1
—
PWR OK
INP1–Source input 1
4
—
2
—
FAULT
INP2–Source input 2
describes the LEDs in on the JNP10K-PWR-DC power supply in an MX10016 chassis.
Table 19: LEDs on a DC Power Supply in an MX10016
Description
State
Color
LED
Indicates that the DC power input voltage is not
within normal operating range.
Blinking
Yellow
INP1 or INP2
DC power is within the operating range (-40 VDC to
-72 VDC).
On Steadily
Green
The power supply is switched off.
Off
Unlit
DC power output is within the normal operating
range.
On Steadily
Green
PWR OK
DC power output is out of the normal operating
range.
Blinking
Yellow
72