Table 11: Fan Tray LEDs on an MX10016 (continued)
Description
State
Color
Name
The left-most SFB behind the right fan tray
is online.
On steadily
Green
SFB 3 status
The beacon feature is enabled. This feature
is enabled using the request chassis
beacon command.
Blinking
Green
An error has been detected in SFB 3.
Replace the SFB as soon as possible. The
SFB is located behind the right fan tray and
is the leftmost SFB in the grouping of 3.
To maintain proper airflow through the
chassis, leave the fan tray installed in the
chassis until you are ready to replace the
SFB.
Blinking
Yellow
The SFB is offline.
Off
None
The center SFB behind the right fan tray
is online.
On steadily
Green
SFB 4 status
The beacon feature is enabled. This feature
is enabled using the request chassis
beacon command.
Blinking
Green
An error has been detected in SFB 4.
Replace the SFB as soon as possible. The
SFB is located behind the right fan tray and
is the middle SFB in the grouping of 3. To
maintain proper airflow through the
chassis, leave the fan tray installed in the
chassis until you are ready to replace the
SFB.
Blinking
Yellow
The SFB is offline.
Off
None
54
Summary of Contents for MX10016
Page 1: ...MX10016 Universal Routing Platform Hardware Guide Published 2019 10 15 ...
Page 19: ......
Page 86: ......
Page 123: ......
Page 153: ......
Page 239: ...Figure 118 Moving the MX10016 Using a Mechanical Lift g100421 242 ...
Page 240: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 245 Alarm Messages 249 ...
Page 241: ......
Page 249: ......
Page 277: ...Restricted Access Warning 281 ...
Page 292: ...Jewelry Removal Warning 296 ...
Page 295: ...Operating Temperature Warning 299 ...
Page 304: ...DC Power Disconnection Warning 308 ...
Page 308: ...DC Power Wiring Sequence Warning 312 ...
Page 311: ...DC Power Wiring Terminations Warning 315 ...
Page 320: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 324 ...