Figure 32: LEDs on a JNP10K-PWR-DC2 Power Supply
g100590
1
2
3
4
3
—
1
—
2–Source input 1
!–FAULT
4
—
2
—
1–Source input 0
OK–Power okay
describes the LEDs on a JNP10K-PWR-DC2 power supply.
Table 20: LEDs on a JNP10K-PWR-DC2 Power Supply
Description
State
Color
LED
Indicates the DC power input voltage is not within
normal operating range.
Blinking
Yellow
1 (INP0 in CLI output) or 2
(INP1 in CLI output)
DC power is within operating range (-40 VDC to -72
VDC).
Solid
Green
The power supply is switched off.
Off
Unlit
DC power output is within normal operating range.
Solid
Green
OK
The output is out of the limits.
Blinking
Yellow
Power supply has failed and must be replaced.
Solid
Red
!
Power supply is functioning normally. Or, only one
input is powered and the enable switch for the input
that is not powered is set to ON. See
DC Power to an MX10016” on page 149
for more
information on the enable switches.
Off
Unlit
74
Summary of Contents for MX10016
Page 1: ...MX10016 Universal Routing Platform Hardware Guide Published 2019 10 15 ...
Page 19: ......
Page 86: ......
Page 123: ......
Page 153: ......
Page 239: ...Figure 118 Moving the MX10016 Using a Mechanical Lift g100421 242 ...
Page 240: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 245 Alarm Messages 249 ...
Page 241: ......
Page 249: ......
Page 277: ...Restricted Access Warning 281 ...
Page 292: ...Jewelry Removal Warning 296 ...
Page 295: ...Operating Temperature Warning 299 ...
Page 304: ...DC Power Disconnection Warning 308 ...
Page 308: ...DC Power Wiring Sequence Warning 312 ...
Page 311: ...DC Power Wiring Terminations Warning 315 ...
Page 320: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 324 ...