LED display
55
(55)
Green LED (charge status)
Lit
Charging complete, battery full. (Charge interval, float
or compensation charge).
Flashes slowly
Charging.
Rapid flash
Display at beginning of charge or after setting a new
characteristic curve. Number of flash pulses
corresponds to the characteristic curve set.
Red LED (fault)
Lit
Overtemperature. Charging is interrupted.
Flashes slowly
Safety charging time exceeded. Charging is cancelled.
Mains must be disconnected for charging to restart.
Rapid flash
Invalid characteristic curve setting.
Compensation charge
The compensation charge starts automatically when charging is complete.
Partial charging
The charger is designed to automatically adapt to partially charged batteries. This
keeps battery wear to a minimum.
64