8.5
Setting the Battery Parameters with CanCode
WARNING!
Altering parameters can cause accidents
u
Altering the settings can cause accidents.
u
This requires greater attention on the part of the
operator
The following example shows the parameter setting
for the battery type (parameter 1377) to "dry -
maintenance-free".
Requirements
– CanCode and CanDis are available.
Procedure
• Press the O key (82).
• Enter the master code.
• Enter the four-digit parameter number "1377" and
confirm with the Set key.
• Enter sub index "2" and confirm with the Set key.
The parameter with subindex are displayed
alternately with the current reading. E.g. (1377-2<-
>0000-1--corresponds to battery type „high-
performance (wet)”.
• Enter parameter "2" according to the parameter list
and confirm with the Set key.
The LED of the O key switches briefly to
continuous light and starts flashing again after
approx. 2 seconds.
If the entry is incorrect, the LED of the O key turns
red. Enter the parameter number again to repeat
the setting.
The parameter and subindex are displayed
alternately with the current reading (1377-2<-
>0000-2).
The "dry maintenance-free" battery type is set.
Z
Travel is disabled while the parameters are being
entered.
Storing the parameter
Requirements
– The parameter is now entered.
Procedure
• Run "SaveParameters" by pressing 1-2-3-Set.
• Press the O key.
80
77
78
79
82
81
145
04.19 en-GB
Summary of Contents for EJC 212z
Page 2: ...2 ...
Page 4: ...4 04 19 en GB ...
Page 10: ...10 04 19 en GB ...
Page 12: ...0506 GB 2 0506 GB 2 ...
Page 27: ...EJC 212z 214z 216z 220z D 25 04 19 en GB ...
Page 50: ...48 04 19 en GB ...
Page 74: ...72 04 19 en GB ...
Page 135: ...Z This setting can be changed if required 133 04 19 en GB ...
Page 193: ...Z After adding hydraulic oil tighten the lock to 10 Nm M 10Nm 191 04 19 en GB ...
Page 195: ...115 113 114 112 193 04 19 en GB ...
Page 226: ...02 16 EN 6 ...
Page 228: ...02 16 EN 8 14 Safety instructions and warning information ...
Page 250: ......