Battery parameters
No.
Function
Range
Standard
setting
Comments
1377
Battery type
(normal / high-
performance / dry-cell)
0 – 5
7
9
1
0 = Normal (wet-cell)
1 = High performance
(wet-cell)
2 = Dry (maintenance-
free)
3 = US "Flat Plate"
type
4 = US "Pallet Pro"
type
5 = US "Tubular
Plate" type
7 = Exide GF12063Y
(Dry battery)
9 = XFC
(Special battery)
1388
ELH battery charger
charging characteristic
0 – 6
1
0 =
No charging function
1 = PzS wet-cell
batteries 100 - 300 Ah
and PzM batteries
from 0 - 179 Ah
2 = PzS wet-cell
batteries with pulse
characteristic 200 -
414 Ah and PzM
batteries from 180 -
400 Ah
3= PzV batteries,
maintenance-free 100
- 150 Ah
4= PzV batteries,
maintenance-free 151
- 200 Ah
5= PzV batteries,
maintenance-free 201
- 300 Ah
6= PzV batteries,
maintenance-free 301
- 333 Ah
1389
Discharge monitor
function
0 / 1
1
0 = Not active
1 = Active
142
04.19 en-GB
Summary of Contents for EJC 212z
Page 2: ...2 ...
Page 4: ...4 04 19 en GB ...
Page 10: ...10 04 19 en GB ...
Page 12: ...0506 GB 2 0506 GB 2 ...
Page 27: ...EJC 212z 214z 216z 220z D 25 04 19 en GB ...
Page 50: ...48 04 19 en GB ...
Page 74: ...72 04 19 en GB ...
Page 135: ...Z This setting can be changed if required 133 04 19 en GB ...
Page 193: ...Z After adding hydraulic oil tighten the lock to 10 Nm M 10Nm 191 04 19 en GB ...
Page 195: ...115 113 114 112 193 04 19 en GB ...
Page 226: ...02 16 EN 6 ...
Page 228: ...02 16 EN 8 14 Safety instructions and warning information ...
Page 250: ......