Flashing sequence / charging curve assignment (ELG 2430)
Flashing sequence
Selected charging curves (characteristics)
0
Truck without battery
1
Wet cell battery: PzS with 100 - 300 Ah
Wet cell battery: PzM with 100 - 179 Ah
2
Maintenance-free: PzV with 100 - 149 Ah
3
Maintenance-free: PzV with 150 - 199 Ah
4
Maintenance-free: PzV with 200 - 330 Ah
5
Wet cell battery: PzS with pulse characteristic 200 -
400 Ah
Wet cell battery: PzM with pulse characteristic 180 -
400 Ah
Wet cell battery: PzS with pulse characteristic 200 -
414 Ah
6
Jungheinrich 100 - 300 Ah
NOTICE
u
All other switch positions (52) block the charger, and the battery is not charged.
u
For PzM batteries with a capacity of less than 180 Ah set characteristic 1, beyond
180 Ah set characteristic 5.
u
With PzS 200-300 Ah wet cell batteries both characteristic curves 1 and 5 can be
used. Characteristic 5 achieves a faster charge.
u
When the battery is connected this allows you to adjust via the charger: If the
switch position is valid the green LED flashes according to the position set; if the
switch position is invalid the red LED flashes.
59
04.19 en-GB
Summary of Contents for EJC 212z
Page 2: ...2 ...
Page 4: ...4 04 19 en GB ...
Page 10: ...10 04 19 en GB ...
Page 12: ...0506 GB 2 0506 GB 2 ...
Page 27: ...EJC 212z 214z 216z 220z D 25 04 19 en GB ...
Page 50: ...48 04 19 en GB ...
Page 74: ...72 04 19 en GB ...
Page 135: ...Z This setting can be changed if required 133 04 19 en GB ...
Page 193: ...Z After adding hydraulic oil tighten the lock to 10 Nm M 10Nm 191 04 19 en GB ...
Page 195: ...115 113 114 112 193 04 19 en GB ...
Page 226: ...02 16 EN 6 ...
Page 228: ...02 16 EN 8 14 Safety instructions and warning information ...
Page 250: ......