– 45 –
ENGLISH
6
1
7
1
6
1
8
0
$5
optical sensor function (Function setting Nos. 235, 236, 237, 238, 239, 242, 247 and 251)
Optcal sensor functon (Functon settng No. 235)
Enable this function if it is to be used.
Before enablng ths functon, assgn the optcal sensor nput wth No. 12.
(Caution) this function is enabled only for the CP-18. For the other operation panels, set the optical
sensor with the switches on the panel.
0 : Optcal sensor functon s dsabled
1 : Optcal sensor functon s enabled
Optical sensor filter function (Function setting No. 236)
This function filters the optical sensor input.
Use this function in combination with Function No. 237: Number of stitches for optical sensor filter.
0 : Optical sensor filter function is disabled
1 : Optical sensor filter function is enabled
Numbers of stitches for optical sensor filter (Function setting No. 237)
The number of stitches for which the optical sensor input is filtered is set.
It is used when Function No. 236: Number of stitches for optical sensor filter is enabled.
0 to 99 sttches
Number of sttches for stoppng the sewng machne after optcal sensor nput (Functon settng No. 238)
The number of sttches to be sewn from the optcal sensor nput to the stop of the sewng machne s set.
(Caution) this function is enabled only for the CP-18. For the other operation panels, set the number of
stitches for stopping the sewing machine after optical sensor input with the switches on the panel.
0 to 99 sttches
Number of tmes of optcal sensor detecton (Functon settng No. 239)
The sewng machne carres out automatc thread trmmng when the set number of tmes the optcal sen-
sor nput s turned ON s reached.
1 to 15 tmes
3
2
5
0
3
2
6
0
$4
Bobbin thread remaining amount detecting function (function setting Nos. 167 and 168)
Enable/disable of the bobbin thread remaining amount detecting function (function setting No. 167)
Enable/disable of the bobbin thread remaining amount detecting function is set in the case the bobbin
thread remanng amount detectng devce s used.
0 : Disabled
1 : Enabled
Bobbn thread remanng amount detectng functon (functon settng No. 168)
Refer to the Instructon Manual for the devce for detals about the settng.
3
2
7
0
Direction of sewing
Sensor signal
Sensor input
No.237
3
2
8
0
3
2
9
1