– 36 –
Output function list
Function code
Abbreviation
Function item
Remarks
0
noP
No function
(Standard setting)
1
TrM
Thread trimming output
Output of thread trimming signal
2
WiP
Thread wiper output
Output of thread wiper signal
3
TL
Thread release output
Output of thread release signal
4
FL
Presser lifter output
Output of presser lifting signal
5
bT
Reverse feed stitching output
Output of reverse feed stitching signal
6
EbT
EBT cancel monitor output
State of one time cancel of reverse feed stitching at end
function is output.
7
SEbT
Reverse feed stitching at start/end cancel
monitor output
State of cancel of reverse feed stitching at start/end is out-
put.
8
AUbT
Sewing start/end cancellation/addition
monitor output
State of cancel or addition of automatic reverse feed stitch-
ing is output.
9
SSTA
Sewing machine stop state output
Sewing machine stop state is output.
10
CooL
Needle cooler output
Output for needle cooler
11
bUZ
Buzzer output
It is output when the bobbin counter set value has been ex-
ceeded, an error has occurred or the bobbin thread remain-
ing amount is detected.
12
LSWo
Revolution command output
Revolution demanding command state is output.
13
vErT
Alternate up/down amount conversion
(monitor) output
Alternate up/down amount conversion signal is output.
14
2PiT
2-pitch output
2-pitch signal is output.
15
bCGo
Bobbin replacement monitor output
Sewing machine start-up prohibition state during bobbin
replacement is output.
16
TC
Thread grasping enabled state monitor
output
Thread grasping enabled state is output.
17
CAbT
S/EBT 1-time cancellation monitor output One-time cancellation state of the reverse feed stitching at
the beginning or end of sewing is output.
18
SToP
Stop state monitor output
Sewing machine operation prohibition state is output.
19
AEbo
Thread remaining amount detecting
device air-blow output
Air blow output when the thread remaining amount detecting
device is used.
20
UdET
Upper position output
Output of needle-up position state
21
ddET
Lower position output
Output of needle-down position state
22
UPWo
Upper position travel state output
Monitor output while the needle goes up to its upper
position.
23
HAWo
Needle up/down correction operation
output
Monitor output while the needle up/down correction
operation is being carried out.
24
TSWo
Tsw command monitor output
Thread trimming command status is output.
25
CUS1
Custom output 1 output
Refer to the Engineer's Manual for details.
26
CUS2
Custom output 2 output
Refer to the Engineer's Manual for details.
27
CUS3
Custom output 3 output
Refer to the Engineer's Manual for details.
28
THLD
Thread clamp output
Output of the thread clamp at the beginning of sewing
which is used in combination with the optical sensor
29
TL2
Tension increasing state monitor output
Monitor output of the OFF state of the thread release
function
30
TrMd
Thread trimming prohibition status
monitor output
Monitor output of the thread trimming prohibition status
31
bTP
Fastening stitch alignment status monitor
output
Monitor output of the fastening stitch alignment status
32
FLTL
Presser lifter and thread release interlock
status monitor output
Monitor output of the presser lifter and thread release
interlock status
33
CGUd
Center guide output
Outputs the center guide
34
CGEM
Center guide control status monitor
output
Monitor output of the center guide control status