– 31 –
ENGLISH
147 Alternate
up/down ntal
output
Sets the status of the alternate up/down output upon turnng the
power on to ether ON or OFF
0: The prevous power-off state s restored
1: OFF s output
2: ON s output
0 to 2
to 2
1 4 7
0
44
148 2-ptch (2-sttch
length) output
durng reverse
feed sttchng at
begnnng/end
of sewng
Carries out 2-pitch output during reverse feed stitching at the
begnnng and end of sewng
0 : The functon s n the OFF state
1 : The functon s n the ON state
0/1
1 4 8
0
44
149 2-ptch nverted
output durng
alternate up/
down output
Sets the nverted output of 2-ptch output s carred out or not n
synchronsm wth alternate up/down output
0 : The functon s n the OFF state
1 : The functon s n the ON state
0/1
1 4 9
0
44
150 2-ptch ntal
output
Selects the status of the 2-ptch output upon turnng the power
on between ON and OFF
0 : The prevous power-off state s restored
1 : OFF s output
2 : ON s output
0 to 2
to 2
1 5 0
0
44
151 Pause and
sttch algnment
functon
Temporarly stops at every corner of the sewng pattern at the
begnnng and end of sewng and durng overlapped sttchng
0 : The functon s n the OFF state
1 : The functon s n the ON state
0/1
1 5 1
0
44
154
Condensation
sttchng
functon for
begnnng/end
of sewng
Enabled when the SC-922 is used in combination with the ma
-
chne head provded wth condensaton sttchng functon for
thread trmmng leavng shorter thread on the materal
The sewng machne performs condensaton sttchng at the be-
gnnng and end of sewng
(Condensation stitching is performed instead of automatic re
-
verse feed sttchng.)
0 : The functon s n the OFF state
1 : The functon s n the ON state
0/1
1 5 4
0
44
155 Settng of the
poston of
carryng out
automatc
presser foot
lftng at neutral
poston of pedal
Automatc presser foot lftng at neutral poston of pedal s car-
red out only when the sewng machne stops wth ts needle
down.
0 : The functon of automatc presser foot lftng at neutral po-
ston of pedal s enabled at all tmes
1 : The automatc presser foot lftng at neutral poston of
pedal s only enabled when the sewng machne stops
wth ts needle down
(Disabled when No. 93 Needle up/down correction switch add
-
ng functon settng s "2.")
0/1
1 5 5
0
38
156 Needle thread
graspng
functon
Enabled when the SC-922 is used in combination with the ma
-
chne head provded wth the needle thread graspng functon
Selects the status of the needle thread graspng functon
0 : ON/OFF wth the operaton enablng swtch
1 : Disables the needle thread grasping function
2 : Forcbly enables the needle thread graspng functon
0 to 2
to 2
1 5 6
0
44
158
Condensation
sttchng
functon durng
thread trmmng
Enabled when the SC-922 is used in combination with the ma
-
chne head provded wth condensaton sttch functon for thread
trmmng leavng shorter thread on the materal
Selects whether or not the condensaton sttch for thread trm-
mng leavng shorter thread on the materal s output
0 : The functon s n the OFF state
1 : The functon s n the ON state
0/1
1 5 8
0
163 Alternate
up/down speed
lmtaton enable
Limits the maximum sewing speed by means of the alternate
up/down amount
Refer to the Engineer's Manual for details.
0/1
1 6 3
0
164 Standng
operaton pedal
nput hgh-
speed swtch
functon
Runs the sewng machne at a hgh speed whenever the stand-
ing operation pedal input exists
0 : The functon s n the OFF state
1 : The functon s n the ON state
0/1
1 6 4
0
167
With/without
bobbn thread
remanng
amount
detecton
Bobbn thread remanng amount detectng devce s used.
However, the bobbn thread counter operates normally regard-
less of the settng of the bobbn thread remanng amount detec-
ton.
0 : The functon s n the OFF state
1 : The functon s n the ON state
0/1
1 6 7
1
45
168 Bobbn thread
remanng
amount
detectng
functon
Sets the functon of the bobbn thread remanng amount detect-
ng devce
Carry out setting referring to the Instruction Manual for the bob
-
bn thread remanng amount detectng devce.
0/1
1 6 8
0
45
174 Thread tenson
changeover
functon
Tenson release functon on one sde s turned ON/OFF n con-
juncton wth other output.
0 : Disabled
1 : Turned OFF when alternate up/down output s turned ON,
and turned ON when alternate up/down output s turned
OFF
2 : Turned OFF upon alternate up/down output, and turned
ON upon thread trmmng
0 to
to 2
1 7 4
0
No
Item
Description
Settng range
Indcaton of functon settng Ref. page
* Do not change the set values with asterisk (
*
) mark as they are functions for maintenance. If the standard set value set at the
time of delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated.
If it is necessary to change the set value, please purchase the Engineer’s Manual and follow the instructions.