Function added to the needle up / down compensating switch (Function setting No. 93)
Operaton of needle up/down compensatng swtch s changed after turnng ON the power or thread trmmng.
0 : Normal (needle up/down compensatng sttchng only)
1 : One sttch compensatng sttchng s performed only when aforemen-
toned changeover s made. (Upper stop / upper stop)
2 : Needle-down functon operates after thread trmmng.
3 : Functon of needle-down wth operaton of 2 plus presser lowerng op-
eraton and needle-up wth thread trmmng operaton s added.
#0
Setting of max. number of rotation of the sewing machine head (Function setting No. 96)
This function can set the max. number of rotation of the sewing machine head you desire to use.
Upper lmt of the set value vares n accordance wth the sewng machne head to be connected.
150 to Max sti/min
< 50 st/mn >
#1
Main shaft reference angle compensation (Function setting No. 120)
Man shaft reference angle s compensated
Setting range
– 60 to 60˚ < 1˚ >
#2
uP position starting angle compensation (Function setting No. 121)
Angle to detect UP poston startng s compensated.
Setting range
– 15 to 15˚ < 1˚ >
#3
DoWN position starting angle compensation (Function setting No. 122)
Angle to detect DOWN position starting is compensated.
Setting range
– 15 to 15˚ < 1˚ >
@9
Continuous sti one shot stitching nonstop function (Function setting No. 94)
This function is used to proceed a step to the next one without stopping the sewing machine at the end
of the step when performng sewng wth the contnuous sewng and one-shot sewng combned usng the
programmng functon of the operaton panel IP.
0 : Normal (Stop when a step has completed.)
1 : The sewing machine proceeds to next step without stopping after a
step has completed.
9 4
0
9 3
0
2
1
0
0
2
1
1
0
2
1
2
0
9 6
0
0
3
0
2
1
4
0
#4
Setting of energy saving function during standby (Function setting No. 124)
It s possble to reduce power consumpton whle the sewng machne s n standby state. It should be noted
that the startup of the sewng machne may delay for a moment f ths functon s set.
0 : Energy-saving mode is ineffective.
1 : Energy-saving mode is effective.
4
1
4
0
4
1
6
0
#5
Number of stitches setting for automatic cancellation of alternate up/down output (function set-
ting No. 144)
Alternate up/down output s cancelled when the set number of sttches has been sewn (0: Automatc can-
cellaton s dsabled). After the alternate up/down output s output by the set number of sttches, output s
turned OFF. When "0" is set, this function does not work. (However, the number of stitches actually sewn
may be larger than the set one accordng to the sewng speed.)
0 : Automatc cancellaton s dsabled
1 to 30 sttches
#6
Selection of alternate up/down output after thread trimming (function setting No. 146)
Alternate up/down output s forcbly turned ON or OFF after thread trmmng.
When this function is set to disable, the alternate up/down output retains the state before thread trimming.
When the set value is "1," the alternate up/down output is brought into the OFF state. When the set value
s "2," the output s brought nto the ON state.
0 : Disabled
1 : OFF
2 : ON