– 10 –
5) Adhere seal
!2
on preset table
!1
by affixing the right and left
edges of the seal at rght and
left markng-off lnes
!3
on the
table.
The locaton of the seal
to be adhered on the preset
table can be found by algn-
ng the scale "21" on the seal
wth markng-off lne
!3
on the
table.
CAUTION:
The marking light is a product categorized under Class 2. Do not look into the beam irradiation
orifices.
6) Turn on the power to the markng lght. Then, move the entre devce to algn the lght beams rradated
from the markng lght wth rght and left markng-off lghts
!3
on preset table
!1
. When the devce s cor-
rectly postoned, securely tghten setscrews
3
(2 x M4).
!2
!1
!1
!2
!3
!3
3-8. Adjusting the marking light
* Settng procedure n the case the dstance from
the edge of placket materal to the buttonhole s
15 mm
1) Loosen setscrews
1
.
2) Turn markng lght
2
n the drecton of the arrow
to adjust the ponter to "15" of the seal adhered
on the preset table so that the laser lght from
markng lght
2
rradates the scale "15."
3) Tghten setscrews
1
takng care not to allow the
laser lght to move out of adjustment.
4) Algn the ponter of the preset table at the scale
"15" on the seal by means of the preset adjust-
ment handle
3
for the adjustng proce-
dure.)
1
2
3