Appendix B Alert, Maintenance INFO and Permanent information
B-70
Message Explanation
Advice
TXRX(LO PLL)
The radar antenna
detected a problem with
the LO frequency.
Restart the device.
TXRX(MHV)
The supply voltage to the
magnetron in the radar
antenna is abnormal.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
TXRX(Option)
The option equipment in
the radar antenna is
abnormal.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
TXRX(PROC)
The radar antenna
detected a problem with
the signal control circuit.
Restart the device.
TXRX(PS)
The power supply circuit in
the radar antenna is
abnormal.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
TXRX(Trigger)
There is possibility that
timing reference signals
are not normally output
from the radar antenna.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
TXRX(Video)
There is possibility that
radar image signals are
not normally output from
the radar antenna.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
VDR(Communication
failed, Main LAN)
Communication with VDR
cannot be performed via
Main LAN.
Check the condition of VDR and Main LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
VDR(Communication
failed, Sub LAN)
Communication with VDR
cannot be performed via
Sub LAN.
Check the condition of VDR and Sub LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Summary of Contents for JMR-7210-6X
Page 2: ......
Page 62: ...Section 19 Adjusting and Setting up Equipment for Services 19 50...
Page 230: ...Section 22 Failures and After Sale Services 22 52...
Page 286: ......
Page 304: ......
Page 426: ...Appendix D Menu List and Materials D 34 D 1 16 Code Input Password ECDIS RADAR CONNING...
Page 585: ......