B-49Appendix B Alert, Maintenance INFO and Permanent information
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP B
Message Explanation
Advice
Log 2(Communication
failed, Direct)
Communication with Log 2
cannot be performed via
Serial.
Check the condition of Log 2 and Serial.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Log 2(Communication
failed, GIF-Direct)
Communication with Log 2
cannot be performed via
Serial.
Check the condition of Log 2, GIF and Serial.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Log 2(Communication
failed, GIF-Main LAN)
Communication with Log 2
cannot be performed via
Main LAN.
Check the condition of Log 2, GIF and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Log 2(Communication
failed, GIF-Sub LAN)
Communication with Log 2
cannot be performed via
Sub LAN.
Check the condition of Log 2, GIF and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Log 2(Communication
failed, Main LAN)
Communication with Log 2
cannot be performed via
Main LAN.
Check the condition of Log 2 and Main LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Log 2(Communication
failed, Sub LAN)
Communication with Log 2
cannot be performed via
Sub LAN.
Check the condition of Log 2 and Sub LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Summary of Contents for JMR-7210-6X
Page 2: ......
Page 62: ...Section 19 Adjusting and Setting up Equipment for Services 19 50...
Page 230: ...Section 22 Failures and After Sale Services 22 52...
Page 286: ......
Page 304: ......
Page 426: ...Appendix D Menu List and Materials D 34 D 1 16 Code Input Password ECDIS RADAR CONNING...
Page 585: ......