21.11 Recovery of the Images in the C
Drive
The backup power supply (DC power supply, etc.) of the equipment must be
connected when recovery of the C drive image is performed. If the power supply
stops during recovery, an accident may occur.
Do not turn off the power supply during recovery of the C drive image.
Otherwise, equipment malfunction occurs, possibly causing an accident.
The operating system (OS) of this equipment runs on the C drive.
The contents of the C drive including the images are stored in the D drive.
When the OS operation on the C drive becomes unstable, the images in the C drive can be written
back from the D drive.
Note
When the images in the C drive are written back, the information relating to C-MAP is cleared.
After writing back of images, re-register the database and license of C-MAP and perform update
as required.
The flow of writing back of images in the C drive is as follows.
Start this equipment with the OS in the D drive
"21.11.1 Starting the equipment with the OS in the D drive"
Execute the SSD recovery tool.
"21.11.2 Executing the SSD recovery tool"
Start the equipment with OS in the C drive.
"21.11.3 Starting the equipment with the OS in the C drive
(Software automatic recovery)"
Re-set C-MAP.
Terminate recovery.
Summary of Contents for JMR-7210-6X
Page 2: ......
Page 62: ...Section 19 Adjusting and Setting up Equipment for Services 19 50...
Page 230: ...Section 22 Failures and After Sale Services 22 52...
Page 286: ......
Page 304: ......
Page 426: ...Appendix D Menu List and Materials D 34 D 1 16 Code Input Password ECDIS RADAR CONNING...
Page 585: ......