60
▋
▋
Maximum rotation(RPM) memory reset
Air speed(A-SPEED)
System List
•
Units of measurement
(UNITS)
•
High speed alarm
(UP ALERM)
:Intermittent tone.
•
Low speed alarm
(DN ALERM)
:Constant tone.
•
Switch select
(SW SEL)
Confirm the low speed alarm starts beeping once activated with the model on the ground.
•
Calibration
(CALIBRATION)
The TLS1-SPD monitors airspeed using a pressure sensor. Sometimes it is necessary to modify the displayed values
slightly because of installation differences, etc. Here you can modify the displayed airspeed by inputting a +/- percentage.
Sub Information display ・ Telemetry set up on display
Select the units to display.
km/h
: To show the speed in km per hour.
mph
: To show the speed in miles per hour.
knot
: To show the speed in knots.
Set the over speed alarm.
The default value is disabled (INH). It is necessary to set a speed to enable the high speed alarm.
The alarm range is from 1 km/h to 999 km/h in 1 km/h steps.
The default value is disabled (INH). It is necessary to set a speed to enable the low speed alarm.
The alarm range is from 1 km/h to 999 km/h in 1 km/h steps.
It is possible to select a switch and/or stick position to determine when the alarms should be active.
▋
(Altitude sensor TLS1-ALT in use)
(Altitude sensor TLS1-ALT in use)
▋
Altitude reset display
The sensor altitude can be made at 0.0m by long pressing the dial.
▋
Highest altitude memory reset
The sensor highest altitude data can be reset at 0.0m long pressing the dial.
▋
Maximum Speed memory reset (Air speed sensor TLS1-SPD in use)
Maximum Speed memory can be reset by long pressing the dial after setting the
display at A-Speed Pop up. Indication of the speed memory shall be reset as “0km/h”
▋
Maximum Value (Ampere/Watt) memory reset
(Power sensor TLS1-PWR in use)
(Rotation sensor in use)
※Each value shall be erased after turning off the main power.
▋
Power sensor display (Power sensor TLS1-PWR)
《Sub-information display》
《Sub-information display》
F-PACK A ( Current)
F-PACK W( Wattage)
F-PACK V ( Voltage)
F-PACK C ( Capacity)
《RPM RPM display》
《Sub-information display》
《Sub-information display》
※ Press continuously
the Rotary Switch for reset.
《F-Pack APop Up》
《F-Pack WPop Up》
When Telemetry Power Sensor(TLS1-PWR) is
used, Select the voltage,capacity,current and
wattage to display.
TIPS
By using the Information screen, it is possible to display your desired Telemetry information on the first page, together
with the Timer and Flight Mode selection on a screen that customers can customize so that it is easy to check. Initially it
is set as Inhibited. Select the telemetry information to be displayed, and allocate it to a position on the screen.
▋
Caution Note
The Telemetry sensor data is meant as an indication only, and therefore we cannot guarantee the accuracy of any
recordings obtained.
Long press the dial to reset
the rpm data.
Maximum value can be reset by long press-
ing the dial. after setting the display at each
AMPERE or/WATT Pop up.