we know what‘s cooking
17/69
Docum
ent
1
0000
028
013
-DO
C
-00
0-0
0-EN
Chilling
AutoTemp 36 and 56
CAUTION!
Watch out for discharging water/steam from the bottom of the kettle when the chilling function
is activated.
The chilling function is used to chill the contents of the kettle.
In technical terms, there are two solutions:
•
Tap water is let in through the steam jacket from where it flows to the floor grate.
•
Chilled water is pumped from an ice bank / chilled water tank through the steam jacket and back to
the ice bank.
In both cases, the steam jacket is filled with water until the temperature of the jacket is decreases to
80ºC, before the chilling process is started. This ensures that there is no pressure in the kettle when the
chilling process is started.
Chilling mode
The kettle’s function depends on whether it is in heating mode or chilling mode. The control panel indi-
cates which mode is active.
Fig. 0-15 Key and LED for chilling
1
LED for heating mode
2
LED for chilling mode
The kettle is switched to chilling mode by pressing
and holding the key down for three seconds until
the LED for heating mode extinguishes and the LED for chilling mode illuminates. If the user attempts to
switch to chilling mode and chilling mode has not been activated in the factory settings menu, error code
U40 will be shown.
NOTICE!
When chilling, depending on the contents of the kettle and stirring there may be a difference be-
tween the temperature shown in the display and the actual temperature of the food.
It is therefore important to check the temperature of the food with another temperature measure-
ment directly in the food.
Setting the set point for food temperature
With the AutoTemp 36 controller, the user cannot set the set point for food temperature, only start and
stop the chilling process.
With the AutoTemp 56 controller, both the set point for food temperature and the required chilling inten-
sity can be set.
The set point for food temperature is set by pressing
so that the display flashes. Set the temperature
set point using the arrow keys.The function will be exited automatically after three seconds without a key
press or if another function is selected.