NOTICE!
To ensure that the food is at the temperature set point, it may be necessary to set the set point
for food temperature lower, e.g. to 1 ºC.
Starting and stopping chilling
Chilling is started/stopped by pressing
.The LED will illuminate when chilling is switched on.
The kettle must be in the vertical position in order to chill. If this is not the case, error code U11 will be
shown and the LED will flash until the kettle has returned to the vertical position or chilling has been
switched off. If the kettle is returned to vertical position within two minutes, chilling will be switched on
automatically again. If it takes longer than this, chilling must be switched on manually again.
NOTICE!
The kettle’s chilling function works best when the contents of the kettle are stirred during chill-
ing. This ensures uniformly distribution of cooling throughout the food.
Setting water consumption for chilling AutoTemp 56
This function is used to set the intensity of the chilling. The lower the value that is selected, the smaller
the quantity of water that passes through the steam jacket and the longer the chilling process will last.
When power step 9 is selected, the flow rate will be set to maximum and the chilling time will be the short-
est possible.
The required chilling power is set by pressing
so that the display flashes. Set the required power using
the arrow keys.The function will be exited automatically after three seconds without a key press or if an-
other function is selected.
Setting water consumption for chilling AutoTemp 36
The required chilling power is set in the user menu point 5.1.
NOTICE!
By this feature, when using open cooling, water consumption can be significantly reduced.
Heating mode
The kettle is switched to heating mode by pressing
and holding the key down for three seconds until
the LED for chilling mode extinguish.
The kettle now performs an initialisation which takes several minutes, as the steam jacket must be emp-
tied of water. During this period, the LED next to
flashes and the kettle can neither heat nor chill.
When the initialisation is complete and the kettle is ready to heat, the LED next to
will illuminate.
AutoTemp 16 and 32
The chilling function is used to chill the contents of the kettle. Chilling takes place by letting water through
the steam jacket down to the floor grate.
NOTICE!
The kettle’s chilling function works best when the contents of the kettle are stirred during chill-
ing. This ensures uniformly distribution of cooling throughout the food.