54/69
Docum
ent
1
0000
028
013
-DO
C
-00
0-0
0-EN
we know what‘s cooking
User menu and factory settings menu
The kettle’s control system depends on a number of parameters which must be set correctly in order for
the kettle to work. These parameters are set in the user menu and the factory settings menu. Only the
parameters that are relevant to the control of the kettle will be shown.As the parameters in the factory
settings menu have an effect on parameters in the user menu, changes must first be made in the factory
settings menu.In ‘Factory data’, users can view the parameters that are set at the factory. Before chang-
ing any parameters, you must be certain that you understand the consequences. If you are unsure, con-
tact your service partner for more information.
Factory settings menu
This group of parameters is set at the factory, so that the settings are appropriate for the kettle’s config-
uration. Furthermore parameters of a more technical kind can be found which normally do not need to
be set.
These parameters will only need to be set in special circumstances such as when a printed circuit board
needs to be replaced.
The factory setting menu is activated by switching off the kettle by pressing
and then pressing
and
simultaneously and holding them down for 10 seconds.
and
must then be pressed simul-
taneously within three seconds.
With the AutoTemp 32, 36, and 56 controllers, the current menu item is shown in the temperature display,
while the water display shows the current value. The value is set using the arrow keys and saved by
pressing water-
.
With the AutoTemp 16 control, the current menu item and the associated value are shown alternately in
the temperature display. The value is set using the arrow keys and saved by pressing heating-
.
When a value has been saved, the next menu item will appear. The factory settings menu is exited when
the last parameter has been saved and the display shows ‘---’.
The factory settings menu will be cancelled if the user presses
or if no key is pressed for two minutes.
Item
Description
Selection
00.0
Shows program
00.1
Shows program version
51.0
Select whether the units are to be altered
0 = No
1 = Yes
Select 1 if 51.1 and 51.2 are to be
shown.
51.1
Select temperature unit
1 = Celsius
2 = Fahrenheit
51.2
Select water quantity unit
1 = Liter
2 = UK Gallon
3 = US Gallon
52.0
Select kettle volume
20-600
53.0
Select heating type
1 = Heated by electricity
2 = Heated by direct steam
54.0
Select the maximum permissible Yescket tem-
perature
1 - 120° celsius
33 - 248° fahrenheit