Weights and Dimensions (Continued)
Table 55:
40–50 Ton Unit Dimensions (inches) with Left and Right Discharge
Unit Configuration
Left Discharge
Right Discharge
J
L2
K
H3
J
L2
K
H3
No ER
W
No Heat
SU with Vertical Filter 4-inch, DP (B, L, R, T)
176.56 28.21
4.65
62.04 176.56 28.21
4.65
62.04
SU with DP (B, L, R, T)
193.56 28.21
4.65
62.04 193.56 28.21
4.65
62.04
SU with Pre-Evap Blank, Small Post-Evap blank, DP (B, L, R, T)
291.56 28.21
4.65
62.04 291.56 28.21
4.65
62.04
SU with Pre-Evap Blank, Large Post-Evap Blank, DP (B, L, R, T)
333.56 28.21
4.65
62.04 333.56 28.21
4.65
62.04
SU with Small Post-Evap Blank, DP (B, L, R, T)
238.56 28.21
4.65
62.04 238.56 28.21
4.65
62.04
SU with Large Post-Evap Blank, DP (B, L, R, T)
285.06 28.21
4.65
62.04 285.06 28.21
4.65
62.04
Heat
SU with Vertical Filter 4-inch, Discharge through Heat Section (B, L)
180.25 40.00 14.09 50.00
N/A
N/A
N/A
N/A
SU with Discharge through Heat Section (B, L)
197.25 40.00 14.09 50.00
N/A
N/A
N/A
N/A
SU with Heat, DP (B, L, R, T)
245.16 28.21
4.65
62.04 245.16 28.21
4.65
62.04
SU with Pre-Evap Blank, Discharge through Heat Section (B, L)
250.25 40.00 14.09 50.00
N/A
N/A
N/A
N/A
SU with Pre-Evap Blank, Heat, DP (B, L, R, T)
298.16 28.21
4.65
62.04 298.16 28.21
4.65
62.04
SU with Pre-Evap Blank, Heat, Small Post-Evap Blank, DP (B,L,R,T)
343.16 28.21
4.65
62.04 343.16 28.21
4.65
62.04
SU with Pre-Evap Blank, Heat, Large Post-Evap Blank, DP (B,L,R,T)
385.16 28.21
4.65
62.04 385.16 28.21
4.65
62.04
SU with Heat, Small Post-Evap Blank, DP (B, L, R, T)
291.56 28.21
4.65
62.04 291.56 28.21
4.65
62.04
SU with Heat, Large Post-Evap Blank, DP (B, L, R, T)
333.56 28.21
4.65
62.04 333.56 28.21
4.65
62.04
E
RW
No Heat
SU with Pre-Evap Blank, Small Post-Evap Blank, DP (B, L, R, T)
366.06 28.21
4.65
62.04 366.06 28.21
4.65
62.04
SU with Pre-Evap Blank, Large Post-Evap Blank, DP (B, L, R, T)
408.06 28.21
4.65
62.04 408.06 28.21
4.65
62.04
SU with Small Post-Evap Blank, DP (B, L, R, T)
313.06 28.21
4.65
62.04 313.06 28.21
4.65
62.04
SU with Large Post-Evap Blank, DP (B, L, R, T)
355.06 28.21
4.65
62.04 355.06 28.21
4.65
62.04
Heat
SU with Discharge through Heat Section (B, L)
271.75 40.00 14.09 50.00
N/A
N/A
N/A
N/A
SU with Heat, DP (B, L, R, T)
319.66 28.21
4.65
62.04 319.66 28.21
4.65
62.04
SU with Pre-Evap Blank, Discharge through Heat Section (B, L)
329.85 40.00 14.09 50.00
N/A
N/A
N/A
N/A
SU with Pre-Evap Blank, Heat, DP (B, L, R, T)
372.66 28.21
4.65
62.04 372.66 28.21
4.65
62.04
SU with Pre-Evap Blank, Heat, Small Post-Evap Blank, DP (B, L, R, T)
417.66 28.21
4.65
62.04 417.66 28.21
4.65
62.04
SU with Pre-Evap Blank, Heat, Large Post-Evap Blank, DP (B, L, R, T)
459.66 28.21
4.65
62.04 459.66 28.21
4.65
62.04
SU with Heat, Small Post-Evap Blank, DP (B, L, R, T)
366.06 28.21
4.65
62.04 366.06 28.21
4.65
62.04
SU with Heat, Large Post-Evap Blank, DP (B, L, R, T)
408.06 28.21
4.65
62.04 408.06 28.21
4.65
62.04
NOTES:
1.
A standard unit includes length for economizer, draw-thru filter, cooling coil, supply fan, and condenser. A standard unit includes a draw-thru (pre-
evaporator) filter with 2-inch angle filter or 2-inch + 12-inch (or 18-inch) filter. Units with a vertical 4-inch draw-thru filter in place of the standard 2-inch
angle or 2-inch + 12-inch (or 18-inch) filter are listed as "SU with Vertical Filter 4-inch."
2.
The heat section includes either gas, hot water, steam, or electric.
3. SU = Standard Unit DP = Discharge Plenum B = Bottom Discharge L = Left Discharge R = Right Discharge T = Top Discharge
4. Dimensions are ± 1 inch.