Johnson Controls
5513350-JTG-1018
105
Weights and Dimensions (Continued)
40–50 Ton Left
Bottom Return Opening with Bottom Supply Opening without ERW
Unit Configuration
AHU
LG
Unit
WD
AHU
Curb
LG
Curb
WD
Cond
LG
Total
LG (E)
A
No Heat
SU with Vertical Filter 4-inch, DP (B, L, R, T)
209.90 96.05 205.40 91.55 87.30 292.70 11.41
SU with DP (B, L, R, T)
226.90 96.05 222.40 91.55 87.30 309.70 11.41
SU with Pre-Evap Blank, Small Post-Evap Blank, DP (B, L, R, T)
See SU with Heat, Small Post-Evap Blank, DP (B, L, R, T)
SU with Pre-Evap Blank, Large Post-Evap Blank, DP (B, L, R, T)
See SU with Heat, Large Post-Evap Blank, DP (B, L, R, T)
SU with Small Post-Evap Blank, DP (B, L, R, T)
271.90 96.05 267.40 91.55 87.30 354.70 11.41
SU with Large Post-Evap Blank, DP (B, L, R, T)
318.40 96.05 313.90 91.55 87.30 401.20 11.41
Heat
SU with Vertical Filter 4-inch, Discharge through Heat Section (B, L)
226.90 96.05 222.40 91.55 87.30 309.70 11.41
SU with Discharge Through Heat Section (B, L)
243.90 96.05 239.40 91.55 87.30 326.70 11.41
SU with Heat, DP (B, L, R, T)
278.50 96.05 274.00 91.55 87.30 361.30 11.41
SU with Pre-Evap Blank, Discharge Through Heat Section (B, L)
296.90 96.05 292.40 91.55 87.30 379.70 11.41
SU with Pre-Evap Blank, Heat, DP (B, L, R, T)
331.50 96.05 327.00 91.55 87.30 414.30 11.41
SU with Pre-Evap Blank, Heat, Small Post-Evap Blank, DP (B, L, R, T)
376.50 96.05 372.00 91.55 87.30 459.30 11.41
SU with Pre-Evap Blank, Heat, Large Post-Evap Blank, DP (B, L, R, T)
418.50 96.05 414.00 91.55 87.30 501.30 11.41
SU with Heat, Small Post-Evap Blank, DP (B, L, R, T)
324.90 96.05 320.40 91.55 87.30 407.70 11.41
SU with Heat, Large Post-Evap Blank, DP (B, L, R, T)
366.90 96.05 362.40 91.55 87.30 449.70 11.41
Unit Configuration
B
RA
WD RA LG
C
D
SA LG
SA
WD
No Heat
SU with Vertical Filter 4-inch, DP (B, L, R, T)
-
72.99 37.63
-
7.27
30.13 77.00
SU with DP (B, L, R, T)
-
72.99 37.63
-
7.27
30.13 77.00
SU with Pre-Evap Blank, Small Post-Evap Blank, DP (B, L, R, T)
See SU with Heat, Small Post-Evap Blank, DP (B, L, R, T)
SU with Pre-Evap Blank, Large Post-Evap Blank, DP (B, L, R, T)
See SU with Heat, Large Post-Evap Blank, DP (B, L, R, T)
SU with Small Post-Evap Blank, DP (B, L, R, T)
-
72.99 37.63
-
7.27
30.13 77.00
SU with Large Post-Evap Blank, DP (B, L, R, T)
-
72.99 37.63
-
7.27
30.13 77.00
Heat
SU with Vertical Filter 4-inch, Discharge through Heat Section (B, L)
-
72.99 37.63
4.40
17.90 40.00 50.00
SU with Discharge Through Heat Section (B, L)
-
72.99 37.63
4.40
17.90 40.00 50.00
SU with Heat, DP (B, L, R, T)
-
72.99 37.63
-
7.27
30.13 77.00
SU with Pre-Evap Blank, Discharge Through Heat Section (B, L)
-
72.99 37.63
4.40
17.90 40.00 50.00
SU with Pre-Evap Blank, Heat, DP (B, L, R, T)
-
72.99 37.63
-
7.27
30.13 77.00
SU with Pre-Evap Blank, Heat, Small Post-Evap Blank, DP (B, L, R, T)
-
72.99 37.63
-
7.27
30.13 77.00
SU with Pre-Evap Blank, Heat, Large Post-Evap Blank, DP (B, L, R, T)
-
72.99 37.63
-
7.27
30.13 77.00
SU with Heat, Small Post-Evap Blank, DP (B, L, R, T)
-
72.99 37.63
-
7.27
30.13 77.00
SU with Heat, Large Post-Evap Blank, DP (B, L, R, T)
-
72.99 37.63
-
7.27
30.13 77.00
NOTES:
AHU = Air Handling Unit LG = Length WD = Width Cond = Condenser RA = Return Air RAR = RA Right RAL = RA Left SA = Supply Air
SU = Standard Unit DP = Discharge Plenum B = Bottom L = Left R = Right T = Top
Table 58:
25–50 Ton Left Bottom Return Opening and Bottom Supply Opening without ERW
(Continued)