Johnson Controls
5513350-JTG-1018
Digit 30: Energy Recovery Options
0: None
1: Low CFM Energy Recovery Wheel (ERW)
without VFD
2: Low CFM ERW with VFD
3: High CFM ERW without VFD
4: High CFM ERW with VFD
Digit 31: Refrigeration System
Piping Options
A: None
B: Suction and Discharge Valves
C: Suction, Discharge, and Liquid Valves
D: Suction, Discharge, and Liquid Valves with
Replaceable Core Filter Driers
E: Hot Gas Reheat (HGRH)
F: Suction
and Discharge Valves with HGRH
G: Suction, Discharge, and Liquid Valves with
HGRH
H: Suction, Discharge, and Liquid Valves with
Replaceable Core Filter Driers with HGRH
N: E-Coat HGRH
P: Suction and Discharge Valves with E-Coat
HGRH
Q: Suction, Discharge, and Liquid Valves with
E-Coat HGRH
R: Suction, Discharge, and Liquid Valves with
Replaceable Core Filter Driers with E-Coat
HGRH
Digit 32: Lights/Detectors/Conve-
nience Options
A: None
B: Convenience Outlet
C: Convenience Outlet and Internal Lights
D: Supply Smoke Detector
E: Return Smoke Detector
F: Supply and Return Smoke Detector
G: Convenience Outlet with Supply Smoke
Detector
H: Convenience Outlet with Return Smoke
Detector
J: Convenience Outlet with Supply and Return
Smoke Detectors
K: Convenience Outlet and Internal Lights with
Supply Smoke Detector
L: Convenience Outlet and Internal Lights with
Return Smoke Detector
M: Convenience Outlet and Internal Lights with
Supply and Return Smoke Detectors
Digit 33: Controls Options
A: None
B: Low Ambient
D: Subcool and Superheat Measurement
E: Low Ambient with Subcool and Superheat
Measurement
Digit 34: Interface Options
A: BACnet
®
MS/TP, Modbus
™
, N2
B: BACnet IP
G: BACnet
®
MS/TP, Modbus
™
, N2 with Mobile
Access Portal (MAP)
H: MAP with BACnet IP
N: BACnet
®
MS/TP, Modbus
™
, N2 with Building
Automation System (BAS) Interface Board
P: BACnet IP with BAS Interface Board
U: BACnet
®
MS/TP, Modbus
™
, N2 with MAP and
BAS Interface Board
V: MAP with BACnet IP and BAS Interface Board
Digit 35: Indoor Air Quality (IAQ)
Options
0: None
1: Ultraviolet (UV) Lights
2: Carbon Dioxide (CO
2
) Sensors, Demand
Controlled Ventilation
3: UV Lights and CO
2
Sensors
Digit 36: Gas Heat Shipped Loose
Kits
0: None
1: Gas Heat, Side Penetration
2: Gas Heat, Bottom Penetration
3: Gas Heat, High Altitude Kit Natural Gas (NG),
Side Penetration
4: Gas Heat, High Altitude Kit NG, Bottom
Penetration
5: Gas Heat, High Altitude Kit Liquid Propane
(LP), Side Penetration
6: Gas Heat, High Altitude Kit LP, Bottom
Penetration
7: Gas Heat, LP Conversion Kit, Side Penetra-
tion
8: Gas Heat, LP Conversion Kit, Bottom
Penetration
Digit 37: Security Options
0: None
1: Supply and Return Opening Burglar Bars
Digit 38: Door Options
0: None
1: Viewport
2: Single Handle with Padlock
3: Single Handle with Padlock and Viewport
Digit 39: Cabinet Shipping Options
1: Single Piece Construction
Digit 40: Curb Options
A: No Roof Curb
C: Pedestal Curb
Digit 41: Pre-Evap Options
0: None
1, 2: Blank Pre-Evap Extension, No Air Blender
3, 4: Blank Pre-Evap Extension, with Air Blender
Digit 42: Shipped Loose Options
0: None
1: Spare Belts for Return/Exhaust
Digit 43: Construction Standard
0: None
Digit 44: Supply Fan VFD Frequency
A–Z: Internal Use Only
Digit 45: Supply Fan Brake
Horsepower
A–L: Internal Use Only
Digit 46: Future 3
0: None
Digit 47: Future 4
0: None
Digit 48: Testing and Special
Quotation (SQ)
0: None
T: Record Test Report
M: Mechanical Special
1: Mechanical Special and Record Test Report
S: Software Special
3: Software Special and Record Test Report
B: Mechanical and Software Special
5: Mechanical and Software Special and Record
Test Report
Digit 49: Generation/Revision Level
1: First Generation
11