REV 02 OCT 2020 JLT4500-IOM-F
16
DANGER
Always load, unload and handle the lift package paying the utmost attention to possible hazards, in particular make sure that there
are no persons or things in the range of the lifting device.
5.2.2 STORAGE
If the lift, before being unpacked, needs a temporary storage, keep it in a covered dry place.
5.2.3 UNPACKING
Once positioned the load close to the point in which the lift shall be installed, remove the eventual packing.
DANGER
Execute any maintenance, installation and assembly operation on the lift wearing proper protective devices (gloves, shoes…).
ATTENTION
All the packing material shall be properly scrapped in respect of the enforced norms in matter of scrapping of refusals.
5.2.4 FOUNDATION
Be certain you have the proper concrete floor to properly handle the loaded lift. Floor should be in generally good condition with no large
cracks, spalling or deterioration.
Floor should be level within 10 mm over the installation area. No anchors should be installed within 200 mm of any crack, edge, or expansion
joint. If these conditions cannot be met, a pad may be poured to accommodate the lift.
Check with local building inspectors and/or permits office for any special instructions or approvals required for your installation.
DANGER
Failure by purchaser to provide the recommended mounting surface could result in unsatisfactory lift performance, property damage,
or personal injury.
Minimum requirements for concrete are:
-
If M16 chemical anchors are used:
200mm minimum depth, un-fissured with steel reinforcement and C20/C25 class minimum
resistance, cured for 28 days per local commercial practice, allowing the fixing to the ground of the lift with the aid of the specified
M16x190 anchors with minimum embedment of 125mm.
-
If HILTI M16 mechanical anchors are used:
200mm minimum depth, un-fissured C20/C25 class minimum resistance, cured for
28 days per local commercial practice, allowing the fixing to the ground of the lift with the aid of the HILTI Anchor HSA-Stud M16
specified anchors with minimum embedment of 132mm.
-
If FISCHER M16 mechanical anchors are used:
200mm minimum depth, un-fissured C20/C25 class minimum resistance, cured
for 28 days per local commercial practice, allowing the fixing to the ground of the lift with the aid of the FISCHER Anchor FBN II
Stud M16 specified anchors with minimum embedment of 104mm.
Summary of Contents for JLT4500S
Page 3: ...REV 02 OCT 2020 JLT4500 IOM F 3 ...
Page 13: ...REV 02 OCT 2020 JLT4500 IOM F 13 Fig 3 General Specifications Service Bay Layout ...
Page 46: ...REV 02 OCT 2020 JLT4500 IOM F 46 9 1 PARTS BREAKDOWN OF FINAL ASSEMBLY Fig 38 FINAL ASSEMBLY ...
Page 54: ...REV 02 OCT 2020 JLT4500 IOM F 54 9 6 PARTS BREAKDOWN OF CARRIAGE AND ARMS ...
Page 64: ...REV 02 OCT 2020 JLT4500 IOM F 64 Check Report Summary Description Date and Name ...
Page 66: ...REV 02 OCT 2020 JLT4500 IOM F 66 12 2 WIRING DIAGRAM FOR SINGLE PHASE SHEET 2 3 ...
Page 67: ...REV 02 OCT 2020 JLT4500 IOM F 67 12 3 WIRING DIAGRAM OF CONTROL BOXES SHEET 3 3 ...
Page 68: ...REV 02 OCT 2020 JLT4500 IOM F 68 12 4 WIRING DIAGRAM OF THE ELECTRICAL SYSTEM ...
Page 70: ...REV 02 OCT 2020 JLT4500 IOM F 70 13 FOUNDATION PLAN ...