MNP37M03GBV00 Date: 24-11 Rev. 0
Page 33 of 79
13
12
15
17
14
19
1
7
4
16
5
9
2
8
6
3
17
Detalle de las posiciones de erogación
en función de la cantidad de café molido
10
11
18
figure 6.07
1.
Infusion chamber
11. Assembly motor rod socket
2.
Upper piston
12. Driving wheel plate
3.
Assembly water inlet
13. Assembly placement arrow
4.
Assembly coffee outlet
14. Guiding rods y assembly attachment
5.
Infusion chamber filter
15. Assembly attachment piston
6.
Upper piston filter
16. Product delivery silicone tube guide
7.
Infusion O-ring
17. Brewing chamber position screws
8.
Upper piston o-ring
18. Brewing chamber lower position
9.
Ground coffee collection funnel
19. Brewing chamber upper position
10. Coffee assembly driving wheel
It is also important that the infusion chamber and brewing chamber O-rings be properly
maintained and replaced whenever a loss in brewing pressure is detected.
To replace the lower o-ring (of the brewing chamber) you need the right tool. We
recommend any type of tool with a diameter under 3 mm (e.g., an allen key) which
is long enough so that it can be inserted in the central hole of the lower filter
support and pushed downwards to release the end of the shaft on which the M-
3x8 mm screw is screwed. After removing the filter support with the o-ring, you
can replace it with another one.