MNP37M03GBV00 Date: 24-11 Rev. 0
Page 74 of 79
Coins with a given value are
not accepted.
Inhibitions wrongly
programmed or return
failure.
Check general inhibitions in
machine address “10”.
Make sure change tubes
have coins (machine
address “02”) and are
working properly (compact
address “27”).
All coins are rejected. No
sale is possible and the
display shows a message
saying the machine is out of
service.
Machine out of service
because the water circuit is
being filled.
Wait for the machine to
finish filling the water
circuit.
All coins are rejected. No
sale is possible and the
display shows a message
saying the machine is out of
service.
Machine out of service
because the water in the
boiler is being heated.
Wait for the machine to
finish heating the water.
NTC error.
Check connection terminals
between the NTC boiler
temperature probe and the
control card.
Check connection terminals
of the boiler heating
element. heck that the solid
state relay is properly
connected to the machine
control card.
Check that the overheat
protection system in the
pressure boiler has not
been triggered.
All coins are rejected. No
sale is possible and the
display shows a message
saying the machine is out of
service.
Machine out of service
because there are no
cups.
Insert cups in the cup
dispenser as indicated on
this manual. Press the cup
dispenser pushbutton and
check they are dispensed
properly.
All coins are rejected. No
sale is possible and the
display shows a message
saying the machine is out of
service.
Machine out of service
because of air break fault.
Check fault in programming
address “18”, try to reset
the fault in address “19”.
Check that the floater is not
stuck, check the cable
harness between the air
break card and the control
card.