MNP37M03GBV00 Date: 24-11 Rev. 0
Page 61 of 79
F
F
ACCESS CODES
LEVEL 1 CODE: 1234
LEVEL 2 CODE: 2345
LEVEL 3 CODE: 3456
LEVEL 4 CODE: 5555
QUICK CHECK CODE: 0000
MOTOR FATIGUE CODE: 0001
RESET CODE: 1505
(Option 35)
ACCESS CODES
Para enter access codes you need to be in the ENTER LEVEL CODE window.
-
RESET: If you enter the RESET code (1505) you will access a menu where you
can delete both Total and Partial accounting data as well as ticket No. You can
alternately carry out a full MEMORY RESET of the machine whereby all
accounting data, sales types and product code links will be deleted. Product doses
and prices will not be deleted.
-
MOTOR FATIGUE: The machine rewrites programming options at different levels
as well as access codes for all levels.
It also rewrites product memory start
addresses. It will therefore be necessary to re-program doses through option
31 after this operation.
11.1.0. –OP_0 price options.
Before programming the prices assign the products to keys. This is because the prices
are assigned to products and not to keys.
To enter press the OK key (key 3). To access a submenu where you can choose
between price programming with money and price programming with card. To select the
programming for sales with money or the price programming for sales with card press
keys 1 and 2. To enter each option, press the OK key.
11.1.0.0 Price programming for sales with money
Viewing level:
In this state you are asked to press the key for which you want to know the
programmed price. Once you have pressed the key the display shows the
price of the associated product. To exit this option press the CANCEL key.
Execute level:
In this state you are asked to press the key for which you want to change the
programmed price. Once you have pressed the key the display shows the
price of the associated product. To change the price, press the OK key. Then
you are asked to enter the price to be programmed in the selection, to
validate, press the programming button, or the sugar pre-selection key. Once
you have carried out this operation the price is automatically recorded for the